DVV F DVV 120 E8302 31 08 15

2 DVV Roof Fan
Motor efciency class
IE2 (single speed)
IE1 (two speed + 8 pole)
IE2 + EMC IE3 + EMC
Model Item No.
DVV/120
Item No.
DVV/F400
Item No.
DVV/F600
Item No.
DVV/120
Item No.
DVV/F400
Item No.
DVV/120
Item No.
DVV/F400
DVV 560D4-XS 95435 95437 95509
DVV 560D4-XM 95434 95436 95510
DVV 560D4-XL 95373 95352 95511
DVV 560D4-6-XL 95414 95413 95512
DVV 630D4-XS 95321 95306 95513
DVV 630D6-XL 95320 95305 95514
DVV 630D4-XL 95318 95303 95515
DVV 630D4-6-XL 95319 95304 Not available
DVV 800D6-XS 95327 95312 95517
DVV 800D4-XS 95326 95311 95518 95482 95489 95438 95444
DVV 800D4-6-XS 95328 95313 95519
DVV 800D6-XL 95323 95308 95520
DVV 800D6-8-XL 95325 95310 95544
DVV 800D4-XL 95322 95307 95521 95483 95488 95439 95445
DVV 800D4-6-XL 95324 95309 95522
DVV 800D4-8-XL 95395 95394 95543
DVV 1000D6-XM 95376 95386 95527 95484 95490 95440 95446
DVV 1000D6-8-XM 95377 95387 95528
DVV 1000D4-XM 95378 95388 95529 95486 95492 95442 95448
DVV 1000D4-6-XM 95379 95389 95530
DVV 1000D4-8-XM 95375 95396 95531
DVV 1000D8-XL 95347 95344 95523
DVV 1000D6-XL 95345 95342 95525 95494 95495 95450 95451
DVV 1000D6-8-XL 95346 95343 95524
DVV 1000D6-12-XL 95374 95385 95526
DVV 1000D8-XP 95381 95397 95533
DVV 1000D6-XP 95382 95390 95532 95485 95491 95441 95447
DVV 1000D4-XP 95383 95391 95534 95487 95493 95443 95449
DVV 1000D4-6-XP 95384 95392 95535
DVV 1000D4-8-XP 95380 95393 95536
Technical data
Tested to 400°C/2h (type F400) respectively 600°C/2h
(type F600), together with frequency converter. However,
we recommend bridging of frequency converter in case of
re to eliminate possible risk of malfunction of frequency
converter. In case of re all motor protective devices
and thermal protections in frequency converter must be
bridged or disabled to guarantee functional capability.
The octagonal casing is manufactured from seawater
resistant aluminium. The base frame is made of hot dip
galvanized steel. Galvanized steel (F400), respectively
inox (F600) impeller with backward curved blades built-in.
Motor cooling with fresh air via air duct. The motor protec-
tion to be provided by customers (PTC built-in electric mo-
tor). For speed control use only combination of frequency
converter and appropriate lter to motor side (sine or
du/dt), observing instalation conditions (e.g. cable type,
lenght). At frequency controlled units additional EMC
protection could be needed (items with EMC protection
built-in recommended).
DVV-XS, XM, XL, XP
Roof Fan for normal ventilation and smoke/heat extract