DVV Roof Fan Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Curtains and Heating Products | Tunnel Fans DVV Roof Fan For normal and high temperature air applications + smoke extraction 1
DVV Roof Fan DVV-XS, XM, XL, XP Roof Fan for normal ventilation and smoke/heat extract The octagonal casing is manufactured from seawater resistant aluminium. The base frame is made of hot dip galvanized steel. Galvanized steel (F400), respectively inox (F600) impeller with backward curved blades built-in. Motor cooling with fresh air via air duct. The motor protection to be provided by customers (PTC built-in electric motor).
DVV Roof Fan Type DVV/120-XS, XM, XL, XP 120°C Type DVV/F400, F600-XS, XM, XL, XP 120°C 400°C 120min • Normal ventilation up to 120°C continuous operation • Normal ventilation + smoke and heat extract (dual use) • Vertical exhaust, suitable for coastal application • Type F400 up to 400°C/120 min (F400/120, F400/90, • IE2 single speed high efficiency motor, IE1 two speed or 600°C 120min F300, F200) 8-pole motor • Type F600 up to 600°C/120 min (F600, F400/120) • Service switch and PTC th
DVV Roof Fan Performance 1000 2000 0 [m³/h] 6000 4000 8000 10000 1200 600 4000 8000 [m³/h] 12000 16000 20000 DVV 630D-XL DVV 630D-XS DVV 560D-XL DVV 560D-XM DVV 560D-XS 800 0 4-pole 900 [Pa] [Pa] 4-pole 600 400 6-pole 0 0 0,3 0,6 6-pole 300 200 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3,0 0 3,3 0 1 2 [m³/s] 2000 0 [m³/h] 20000 10000 30000 40000 1000 0 10000 3 [m³/s] 500 [Pa] [Pa] 4-pole 500 250 6-pole 2500 0 2 0 4 10000 12-pole 6 [m³/s] 20000 8
9 61 4 55 620 14 690 14 DVV Roof 8Fan 12 x M 8 5 10 3 10 9 93 94 964 990 1500 345 1500 1350 345 1100 289 675 581 451 361 800 800 630 560 9, 51 1490 2 1663 5 7, 62 5 690 8 16 x M 10 12 10 12 10 1050 39 84 0 75 9 3 94 93 35 0 50 5 7, 62 16 8 12 x M 8 12 x M 800 860 14 51 14 55 620 x 80 14 675 14 M 0 9 61 4 55 8 86 0 47 1490 DVV 630 892 311 DVV 800D6-XS DVV 800D4-XS DVV 800D6-XL 1105 DVV 560 39 84 0 75 Dimensions 35 0 12
Starting 6 Lock in position ON to prevent unintended switch OFF DVV Roof Fan OFF Y 400V L1 L2 L3 PTC PTC Max. 2.
DVV Roof Fan 7 DVV-XS, XL installation examples DVV SSG/F DVV VKG/F ASSG/F ** ASG/F * VKG/F ASSG/F * Note: if the fan is intended for emergency use only, the shutter below roof base could lead to condensation on the non-insulated base plate of the fan (low air change rate) ** Inlet cone for improving inlet conditions; it is not possible to mount it into socket silencers Accessories Details of following and electrical accessories are on-line available.
Systemair d.o.o. · August 2015 · E8302 www.systemair.