Smoke extract roof fans Roof Fan DVG Smoke extraction and daily ventilation in one.
DVG/F Smoke and heat extract roof fan -H DVG-H -V DVG-V Horizontal exhaust Vertical exhaust • Smoke and heat extract unit + normal ventilation • Up to 400°C/120 min (F400/120, F400/90, F300, F200) • Normal ventilation up to 120°C continuous operation • Vertical exhaust DVG-V or horizontal DVG-H • Includes pre-wired service switch • Suitable for coastal applications • Wide range of accessories • Tested acc. to EN 12101-3 at LGAI, Barcelona • CE-certified acc.
DVG installation examples and accessories DVG-V DVG-V VKG/F Automatic shutter SSG/F Roof baseSilencer with silencer ASSG/F Flexible connection FDG/F Roof base Silencer ASG/F Inlet chamber VKG/F Automatic shutter ASSG/F Flexible connection DVG-V DVG-V VKG/F Automatic shutter VKG/F Automatic shutter SSGE/F (FDGE/F) Silencer Roof base with or without silencer SSG/F Silencer Roof base with silencer ASG/F Inlet chamber ASG/F Inlet chamber ASSG/F Flexible connection ASSG/F Flexible connection Acces
Diagrams qv [m³/h] qv [m³/h] DVG-H 355 DVG-V 355 DVG-H 315-XL DVG-V 315-XL 4-pole 4-pole 6-pole 6-pole 8-pole 8-pole qv [m³/s] qv [m³/s] qv [m³/h] qv [m³/h] DVG-H 400-XL DVG-V 400-XL DVG-H 400-XS DVG-V 400-XS 4-pole 4-pole 6-pole 6-pole 8-pole qv [m³/s] qv [m³/s] qv [m³/h] qv [m³/h] DVG-H 500-XS DVG-V 500-XS DVG-H 450 DVG-V 450 4-pole 4-pole 6-pole 6-pole 8-pole qv [m³/s] 4 systemair qv [m³/s]
qv [m³/h] qv [m³/h] DVG-H 500-XL DVG-V 500-XL DVG-H 560 DVG-V 560 4-pole 4-pole 6-pole 6-pole 8-pole 8-pole qv [m³/s] qv [m³/s] qv [m³/h] qv [m³/h] 4-pole DVG-H 630-XS DVG-V 630-XS DVG-H 630-XM DVG-V 630-XM DVG-H 630-XL DVG-V 630-XL 4-pole 6-pole 6-pole qv [m³/s] qv [m³/s] qv [m³/h] 6-pole DVG-H 800-XL DVG-V 800-XL DVG-H 800-XS DVG-V 800-XS 8-pole qv [m³/s] systemair 5
Technical data Item No. Model DVG-H / F400 Max. airflow [m³/h] Current [A] Sound pressure level at 4/10m [dB(A)] Weight [kg] Motor connection / wiring Wiring diagram Erp 2018 95619 315D4-XL 2930 0.67 0.26 1466 58/51 39 Y 3 ✓ 95620 315D6-XL 1950 1.00 95621 315D4-6-XL 2930 / 1950 1.15 / 0.52 0.17 971 46/40 39 Y 3 - 0.38 / 0.18 1469 / 969 58/51 / 46/40 40 Y/Y 2 - 95622 315D4-8-XL 2930 / 1380 95003 355D4 3100 1.15 / 0.50 0.32 / 0.
Item No. Model DVG-V / F400 Max. airflow [m³/h] Current [A] Sound pressure level at 4/10 m [dB(A)] Weight [kg] Motor connection / wiring Wiring diagram Erp 2018 95647 315D4-XL 2720 0.67 0.26 1465 56/50 41 Y 3 ✓ 95648 315D6-XL 1800 1.00 95649 315D4-6-XL 2720 / 1800 1.10 / 0.52 0.15 971 46/40 41 Y 3 - 0.38 / 0.18 1469 / 969 56/50 / 46/40 42 Y/Y 2 - 95650 315D4-8-XL 2720 / 1280 32308 355D4 2900 1.15 / 0.50 0.32 / 0.
Dimensions DVG-H A B G ø d1 ø d2 ø d3 nxM ø d4 øD E H1 H 315 598 450 704 224 310 438 6xM8 12 400 240 30 580 355 598 450 704 224 310 438 6xM8 12 400 240 30 580 400 668 535 854 286 379 438 6xM8 12 400 240 30 650 450 668 535 854 286 379 438 6xM8 12 400 240 30 650 500 943 750 1078 361 450 620* 12xM8 14 560 240 30 773 560 943 750 1078 361 450 620* 12xM8 14 560 240 30 773 630 1039 840 1072 451 570 690* 12xM8 14 630
Wiring diagrams* ON U1 V1 W1 U2 V2 W2 PTC PTC NO NC PE Starting OFF Y 400V L1 L2 L3 PTC PTC Max. 2.5V PE Wiring D; single speed motor, recommended to start star-delta. ON Wiring Y or D, depending on motor type, prewired inside fan; single speed motor. U1 V1 W1 PTC PTC NO NC PE OFF ON U1 V1 W1 U2 V2 W2 PTC PTC NO NC PE Operation 400V OFF D 400V L1 ON L2 L3 PTC PTC Max. 2.5V 1U 1V 1W 2U 2V ON L2 L3 2W PTC PTC NO NC PE PTC PTC Max. 2.5V 1U 1V 1W 2U 2V L3 PTC PTC Max. 2.