EDM SyScroll 40 75 Air

|
SyScroll 40-75 Air
18
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
WaterWater + Glycol + EEV
Water + Glycol + EEV +
Fan speed controller
Water+
Fan speed controller
Leaving water temperature (°C)
Leaving water temperature (°C)
Air temperature (°C)
Air temperature (°C)
-9 -10 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 20191817161514131211
18 20 22 24 26 28 30 32 34 36 38 40 42 44 565452504846
-12
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
14
16
18
20
22
Cooling mode
Heating mode
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
WaterWater + Glycol + EEV
Water + Glycol + EEV +
Fan speed controller
Water+
Fan speed controller
Leaving water temperature (°C)
Leaving water temperature (°C)
Air temperature (°C)
Air temperature (°C)
-9 -10 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 20191817161514131211
18 20 22 24 26 28 30 32 34 36 38 40 42 44 565452504846
-12
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
14
16
18
20
22
SyScroll 40-75 Air CO/HP SLN
Operating limits are referred to full load (2 compressors running).
Maximum glycol% (ethylenic or propilenic)= 40%.
Operating Limits