Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating Products | Tunnel Fans Ecodesign in SystemairCAD A quick guide to Ecodesign ErP 2016 ErP 2018
Ecodesign i SystemairCAD Ecodesign To reduce products’ energy consumption, the European Union has introduced new legal requirements – the Ecodesign standards – in order to remove the least energy efficient products from the market. This is an important part of the plan that will make it possible to fulfil the EU’s 2020 Energy and Climate goals. The new Ecodesign standards apply to a long list of energy related products, including the product category: Air Handling Units.
Ecodesign in SystemairCAD | Ecodesign in SystemairCAD Bidirectional ventilation unit (Heat recovery units) | 2/2 30-03-2017 Air handling unit design | SystemairCAD 2.0 Version C2017-04.00.00-beta07 | Geniox Comfort 12DR | Project: The selection software SystemairCAD is updated with an automatic Ecodesign calculation that will tell you whether the requirements for both 2016 and 2018 are fulfilled. All calculation details are summarised in the technical documentation.
| Pressure gauge (exclusively for 2018) Approved SFPint in W/(m³/s) Approved Total check Approved Ecodesign in SystemairCAD Approved 904 1414 Approved 904 Supply Extract VSD VSD Installed 1.33 1.33 m³/s Effective electric power input incl. clean filters and variable drive 1.36 1.
Ecodesign in SystemairCAD Ecodesign What does this mean for you as a customer at Systemair? As a general rule, Systemair’s air handling units are prepared for the Ecodesign requirements in both 2016 and 2018. If the air handling unit is designed in an energy efficient way, all legal requirements are automatically fulfilled. Ecodesign implies that extra mandatory Ecodesign data will be added to Systemair’s technical documentation.
| Ecodesign in SystemairCAD Ecodesign in SystemairCAD 30-03-2017 Air handlingventilation unit design | SystemairCAD 2.0 Version C2017-04.00.00-beta07 | Geniox Comfort 11.055IR Unidirectional unit (Supply-/Extract units) | 2/2 | Project: Ecodesign Air handling unit with filters 2016 Value Limit 2018 Value 1 Non Residential - Unidirectional Approved Approved 2 Fan with multispeed or Var.Speed Drive Approved Approved Limit 3 Pressure 30-03-2017 Air handling unitfor design 2.
Ecodesign in SystemairCAD | 3 4 Pressure gauge (Exclusively for 2018). If the air handling unit has a filter installed, it must be equipped with a visual alarm signal or an alarm in the control system, if the pressure above the filter exceeds the maximum allowed pressure drop. 5 Specific Fan Power For an extract/supply unit without any filter, there are some specific fan power demands (SFP). SystemairCAD calculates the limit value as well as the actual specific fan power value of the air handling unit.
Avedøreholmen 88 DK-2650 Hvidovre Tel. +45 87 38 75 00 mail@systemair.dk www.systemair.