Geniox GO User manualv7.2
Table Of Contents
- A Manufacturer
- B Name of machines
- C Declaration of Conformity
- D General descriptions, dangers and warnings
- E The control panel for the control system.
- F Drawings, diagrams, guides and instructions for the use, maintenance and repair
- G Employees in charge of operation/control/maintenance
- H Unintended use and misuse – inappropriate applications for the machine
- I Instructions for unloading and handling on site
- J Installation
- J.1 Installation - mechanical
- J.1.1 Free area in front of and above the unit
- J.1.2 Supporting surface
- J.1.3 Adjustable feet under legs or base frame and transport of sections
- J.1.4 Base frame assembly
- J.1.5 Base frames for outdoor units
- J.1.6 Outdoor units — support under the base frame of the unit
- J.1.7 Installation on the site of unit sections at the base frame when sections are delivered on pallets
- J.1.8 Joining the unit sections
- J.1.9 Fitting the ductwork
- J.1.10 Risk of stack effect by vertical ducts and wind pressure on louvers
- J.1.11 Door alignment
- J.1.12 Lock the doors by using the key
- J.2 Installation - electrical
- J.3 Installation – Pipes for water – hot and chilled, valves and drains
- J.1 Installation - mechanical
- K Installation and assembly instructions for reduction of noise and vibration emissions
- L Start-up, adjustments, use and commissioning
- M Information about the residual risks
- N Instructions on the protective measures during repair and maintenance
- O The essential characteristics of tools which may be fitted to the machinery
- P The conditions of stability during use, transportation, assembly, dismantling when out of service
- Q Instructions for machinery where these are regularly to be transported
- R The operating method to be followed in the event of breakdown. Safe restart.
- S Adjustment and maintenance operations
- T Instructions to enable adjustment and maintenance safely
- U Information on airborne noise emissions exceeding 70 dB(A)
- Annex 1 Technical data – unique data for every unit (in separate cover)
- Annex 2 Assembly of base frame – height 118 mm for unit sizes 10 – 18
- Annex 3 Assembly of base frame – height 118 mm for unit sizes 20 – 27
- Annex 4 Assembly of base frame – height 218 mm for unit sizes 10 – 18
- Annex 5 Assembly of base frame – height 218 mm for unit sizes 20 – 27
- Annex 6 Installation of steel roof in the sizes 10 – 31
- Annex 7 Speed control for rotor and assembly of divided rotor
- Annex 8 Reversible heat pump unit (in separate cover, if heat pump was delivered)
- Annex 9 Menu for internal controller in the heat pump unit (in separate cover, if heat pump was delivered)
- Annex 10 Connection of fan motor and set-up manual for frequency converter
- Annex 11 Commissioning protocol (in separate cover)
- Annex 12 Report with data from final functional test on the Systemair factory
- Annex 13 Short description of main components in the control system
- Annex 14 Wiring diagram (in separate cover)
- Annex 15 Operator’s guide (How to use the Systemair control panel) (in separate cover)
10
| Instructions for unloading and handling on site
Caution
It is strictly forbidden to lift a section under the top of
the section. The plastic corners and brackets are not
at all reinforced for lifting the unit under the top.
There is serious danger that the bottom with the
heavy components will fall down with the risk of
serious injury and damage to property.
Caution
If base frame has 4 forklift holes section must be
lifted evenly using two forklifts. There is a risk of
overturning resulting serious injury and damage to
property if section is lifted unevenly or only by one
forklift.
Important
• Transportation must be performed by specialised personnel (truck operators, hook- up personal),
equipped with the necessary protection equipment.
• The AHU must be transported and stored in such a way that it is protected against physical damage.
• During transportation the unit must always be in the upright position and tilted less than 15˚.
• If sections must be tilted more than 15 degrees, sections with fans or rotating exchangers that can be
drawn out for service must be secured carefully.
• During transportation, suction pipe of the compressor must always point upwards to prevent the leakage
of oil from the compressor pump.
• Doors of the units must always be closed during transport.
Important
• Only approved hoisting equipment with sufficient load capacity must be used for lifting.
• All lifting devices, ropes, straps etc, must be selected by someone with the required knowledge and be
fully responsible for the use.
• The hoisting equipment must be in perfect condition.
• Lifting gear must be checked for load capacity and damage before use.
• The overhanging drip edges must be safeguarded by additional measures during crane transport (e. g.
traverses or wooden spacer beams).
• Even lifting of the unit/section must be assured.
• Lifting may only be performed using permitted attachment points.
• Ensure that the method of lifting does not allow the unit to slip from chains and slings and does not allow
the unit to turn over or slide from lifting devices.
The manufacturer will not accept any responsibility in case of possible accidents due to the non-observance of these
warnings
211728 | v7.2