Geniox GO User manualv7.2
Table Of Contents
- A Manufacturer
- B Name of machines
- C Declaration of Conformity
- D General descriptions, dangers and warnings
- E The control panel for the control system.
- F Drawings, diagrams, guides and instructions for the use, maintenance and repair
- G Employees in charge of operation/control/maintenance
- H Unintended use and misuse – inappropriate applications for the machine
- I Instructions for unloading and handling on site
- J Installation
- J.1 Installation - mechanical
- J.1.1 Free area in front of and above the unit
- J.1.2 Supporting surface
- J.1.3 Adjustable feet under legs or base frame and transport of sections
- J.1.4 Base frame assembly
- J.1.5 Base frames for outdoor units
- J.1.6 Outdoor units — support under the base frame of the unit
- J.1.7 Installation on the site of unit sections at the base frame when sections are delivered on pallets
- J.1.8 Joining the unit sections
- J.1.9 Fitting the ductwork
- J.1.10 Risk of stack effect by vertical ducts and wind pressure on louvers
- J.1.11 Door alignment
- J.1.12 Lock the doors by using the key
- J.2 Installation - electrical
- J.3 Installation – Pipes for water – hot and chilled, valves and drains
- J.1 Installation - mechanical
- K Installation and assembly instructions for reduction of noise and vibration emissions
- L Start-up, adjustments, use and commissioning
- M Information about the residual risks
- N Instructions on the protective measures during repair and maintenance
- O The essential characteristics of tools which may be fitted to the machinery
- P The conditions of stability during use, transportation, assembly, dismantling when out of service
- Q Instructions for machinery where these are regularly to be transported
- R The operating method to be followed in the event of breakdown. Safe restart.
- S Adjustment and maintenance operations
- T Instructions to enable adjustment and maintenance safely
- U Information on airborne noise emissions exceeding 70 dB(A)
- Annex 1 Technical data – unique data for every unit (in separate cover)
- Annex 2 Assembly of base frame – height 118 mm for unit sizes 10 – 18
- Annex 3 Assembly of base frame – height 118 mm for unit sizes 20 – 27
- Annex 4 Assembly of base frame – height 218 mm for unit sizes 10 – 18
- Annex 5 Assembly of base frame – height 218 mm for unit sizes 20 – 27
- Annex 6 Installation of steel roof in the sizes 10 – 31
- Annex 7 Speed control for rotor and assembly of divided rotor
- Annex 8 Reversible heat pump unit (in separate cover, if heat pump was delivered)
- Annex 9 Menu for internal controller in the heat pump unit (in separate cover, if heat pump was delivered)
- Annex 10 Connection of fan motor and set-up manual for frequency converter
- Annex 11 Commissioning protocol (in separate cover)
- Annex 12 Report with data from final functional test on the Systemair factory
- Annex 13 Short description of main components in the control system
- Annex 14 Wiring diagram (in separate cover)
- Annex 15 Operator’s guide (How to use the Systemair control panel) (in separate cover)
18
| Installation
3. Pull sections together with straps. We recommend the shown type of straps because this type is not damaging the
bottom frame profiles of the units. Place the strap on the bottom profiles of the unit to avoid any load and stress
on the plastic corners created by the tensioner when sections are pulled together.
Note! Do not place the strap on the vertical profiles because the
plastic corners and the profiles are not at all reinforced for the
heavy load and stress that is created by the tensioner. To avoid
any load and stress on the plastic corners the strap must be
carefully placed on the bottom profiles of the unit when sections
are pulled together.
Place the strap on the bottom profiles of the unit to avoid any
load and stress on the plastic corners created by the tensioner
when sections are pulled together.
The sections must be pulled fully and tight together with the
strap is placed on the bottom profiles. Do not pull and slide a
section unless the strap is placed on the bottom profile.
When the sections are pulled fully together it may be helpful
to place the strap halfway up on the unit to press the sections
fully together so that the rubber seals are closing 100% tight.
Only gentle tension is allowed because the vertical profiles are
not reinforced for brutal stress in this direction and they may
be bent. Instal delivered brackets before the strap is removed.
4. Sections are mounted to base frames with self-drilling screws. In the base frame you will find a sufficient number
of 5 mm holes that are prepared for the self drilling screws.
211728 | v7.2