eCAN_V1.0_Spec_Sheet_Eng_DM v1.0.1

SystemBase Co., Ltd.
16F, Digital-ro 288, Guro-gu, Seoul, Republic of Korea 08390
Tel +82-2-855-0501 | Fax +82-2-855-0580 | www.sysbas.com
Specifications subject to change without notice
Overview
Specification
LAN
LAN Port
10/100Mbps, MDI/MIDX RJ-45 Port x 1EA
Network Connection Static IP, Dynamic IP
Protocols TCP, UDP, ICMP, DHCP, HTTP
CAN
Port
1 Port DB9 (Male)
Speed Max. 1Mbps
Standard CAN 2.0 A/ CAN 2.0 B
Signals CAN_H, CAN_L
Hardware
Power Requirement 5V 1A DC Input, Power Consumption: 0.95w
Power Connector Outer Φ3.5mm, Internal Φ1.35mm
Dimension (W x L x H) 40.9 x 74.5 x 16.5mm (1.61 x 2.93 x 0.65in)
Weight 32.1g (1.13oz)
Operating Temperature -40 ~ 85℃ (-40 ~ 185℉)
Humidity Max. 95% R.H
LED RDY(Yellow), Data(Red), LINK(Green),
Protection ±15kV ESD Protection
Software
Operating Mode COM Redirector, TCP Server,/Client, UDP Server/Client
Utility Redirector, eCANView
Configuration Web, eCANConfig
Ordering Information eCAN V1.0
eCAN is a gateway converter that connects various types of CAN equipment to a network(such as
inspection/instrumentation equipment, communication related devices, data output devices, industrial equipment,
etc). eCAN supports CAN 2.0 A and CAN 2.0 B and provides wired LAN network connections which can be
automatically detected and connected from remote locations.
It can be used in connection with a vehicle inspection/measurement/monitoring device or with an industrial
equipment, to perform monitoring/control/data collection of CAN devices from a remote area over the network.