Serial Setting
You can set the operating environment for serial ports in the Serial Settings page. Once you have changed the settings, you
must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply them to actual
equipment operation. If you exist without saving the changes, the changed value will be lost.
If you have not saved the modified value by the [Submit] button, you can return to the value before changing with the [Cancel]
button.
If Operation Mode is COM Redirector in the Operation Settings, the current serial settings are ignored and changed to the
settings when the virtual COM Port is connected.
The main features of the Setup Menu are as follows:
Menu Default Description
Interface RS-232 Set the interface of the serial port(Option: RS-422/485)
Termination
Register
Disable Set the termination resister when the serial is RS-422 or RS-485.
RS-422 Multi-
Drop Mode
Master
Set the operation mode when serial communication is made in RS-422
interface. Set Master to Master, Slave to Slave in RS-422 Multi-Drop
configuration. For 1:1 connection other than RS-422 Multi-Drop mode, set both
connecting equipment to Master.
Baud Rate 9600 bps
Set the communication speed of the serial port
(Option: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400, 460800, 921600bps)
Data Bits 8
Set the number of bits which make up the byte
(Option: 5, 6,7,8)