User's Manual
-13- -14-
GSM anti-theft alarm controller GSM anti-theft alarm controller
Operating method: [26] [02] [1] [#]
LCD display:
9.3 Wired Detector Alarm Type Setting
In setup state, input number [47], and press the defense zone number[81~88] and then input
[0~3] about detector alarm type, finally press [#] to confirm. The host makes a “tick” sound, and
then a voice prompts “setting completed”.
Operating method: [47] [XX] [Y] [#]
XX indicates: two-digit defense zone number
Y indicates: one defense zone alarm type
Notes: wired defense zone of Z1 is equal to zone of 81, wired defense zone of Z2 is equal
to zone of 82, wired defense zone of Z8 is equal to zone of 88 in turn
Example: alarm type about defense zone of Z2 is set to Out Arm or Stay Arm
Operating method: [47] [82] [1] [#]
LCD display:
10. Wireless Siren Coding Setting
In setup state, input [28]+8-digit wireless siren coding, then enter [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”.
Note: Wireless equipment coding includes sc2262 coding four data bits & 8 address bits.
Operating method:[28] [XXXXXXXX] [#]
XXXXXXXX indicates:8-digit wireless siren coding
Example: detailed operating of wireless equipment coding is“01020102”
Operating method:[28] [01020102] [#]
LCD display:
11. Remotes Operation Voice Prompt Setting
In setup state, input number [31], and then input 0/1 , finally press [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”. Factory defaults: turn on
the voice
[ ]
Operating method: 31] [X] [#]
X =“0” indicates:Voice prompt turns off
X =“1” indicates:Voice prompt turns on
Example: Turn on remotes voice prompt
Operating method:[31] [1] [#]
[
LCD display: