Installation
For ChekPoint Models with Above Deck Temperature Mixing Valves
Note: If installing to an existing ChekPoint faucet which is in use, shut
Note: If installing to an existing ChekPoint faucet which is in use, shut
o the water at the supply stops and unplug and disconnect the plug-in
o the water at the supply stops and unplug and disconnect the plug-in
wall transformer if in use. The batteries located within the body may be
wall transformer if in use. The batteries located within the body may be
left installed if desired. (See the applicable ChekPoint faucet manual for
left installed if desired. (See the applicable ChekPoint faucet manual for
instructions on accessing the batteries.)
instructions on accessing the batteries.)
1. Disconnect the faucet cold water exible supply line from the check valve
adapter. The check valve adapter can stay connected to the cold water
supply stop if already connected.
2. Connect the check valve adapter to the ½” NPSM swivel coupling supplied
with the Hydro Generator.
3. Connect the other end of the ½” NPSM swivel coupling to the inlet on the
bottom of the Hydro Generator. Note the blue ow direction arrow on the
side of the Hydro Generator.
4. Connect the check valve adapter swivel end to the cold water supply stop
if not already connected from step 1.
5. Connect the outlet on top of the Hydro Generator to the faucet cold water
exible supply line.
6. Connect the power cable from the Hydro Generator to the wire connector
coming from the faucet bottom (wire may be wound and tucked into the
opening in the faucet bottom).
7. Should the ChekPoint faucet sensor range need adjustment, refer to the
applicable ChekPoint faucet manual for instructions.
6
5
4
4
2
1
5
3
6
SENSOR RANGE SETUP
Models with blue below deck control modules:
The sensor range is preset at the factory during assembly but can be further adjusted by using the steps below.
1. The sensing distance is adjustable from ¾” (2cm) to 6 11/16” (17cm). If there is a disruption in power, the sensor
range is saved and will revert to the last setting when power is restored.
2. The faucet sensor range is set by simply using the on/o button on the front of the control module. Do not
attempt to open the control module box.
3. Push and hold the on/o button; water will ow. After holding the button 5 to 7 seconds, the water ow will stop
and the red LED in the sensor lens will turn on solid.
4. Release the on/o button. The red LED will turn o signaling that the sensor is ready for set-up for the next 15
seconds.
5. Hold your hand still in front of the sensor at the desired sensor distance. The red LED will ash roughly 5 times
then remain on for 2 seconds indicating the new range has been set.
6. If step 5 is not done within 15 seconds, the red LED will blink quickly then stop indicating the sensor range has