Installation
5
2. If supply side Tee is female, apply
Teflon Tape or sealant to threads of a
pipe Nipple (not supplied), and thread
Nipple into female pipe Tee. Then,
thread onto exposed thread of Nipple,
no.4, and tighten.
3. Apply thread Teflon Tape or sealant
to male thread of no.1 Connector.
Thread male no.1 Connector into no.4
and tighten.
General Instructions
Appliance Side
(Without Quick Disconnect - no.5)
1. Apply Teflon Tape or sealant to
Appliance’s male Stub and thread no.3
(Female to Female) to male Stub.
2. Apply Teflon Tape or sealant to male
thread of no.1 connector. Thread no.1
connector into no.3 (Female to Female)
at appliance and tighten.
Appliance Side
(With Quick Disconnect)
1. Apply Teflon Tape or sealant to
Appliance’s male Stub and thread no.2
(Male to Female) to male Stub.
2. Separate no.5 Nipple half from
Coupling half. Apply Teflon Tape or
sealant to male threads on no.2 (Male/
Female).
3. Thread Nipple half of no.5 onto no.2
(Male/Female) at appliance and
tighten.
4. Reconnect no.5 halves.
WARNING: No.5 must be oriented
so fluid enters Coupling half and
exits Nipple half. Follow flow
direction arrows marked below and
no.5 itself.
Coupling
Half
Nipple
Half
Flow Direction
Finishing and Testing
1. Check tightness of all connections
and perform leak test.
2. After installation of no.1 Connector,
carefully push appliance back to
operation position and check that no.1
connector is not kinked, overbent, or
caught under appliance casters.
3. If no.6 will be used, install device
and set length so no.1 connector is
never fully extended.