Instructions / Assembly
For Retro-Fit of Glass Filler Only
1. Turn off water supply and drain lines.
2. Heat cube & unscrew glass fi ller from cube.
3. Apply Loctite 680, tefl on tape or joint compound to the threads of no.6.
Screw into cube of no.14, then align and tighten no.6. Let Loctite 680 sit for 20
minutes.
4. Turn on water supply and check for leaks.
General Instructions
14
15
17
16
6
5
cube
For Glass Filler Valve Repair Kit
1. Unscrew no.21 with fl athead screwdriver.
2. Remove no.7 spring.
3. Place new no.21 and no.7 into no.6.
4. Screw no.21 until fl ush with no.6.
6
7
21