Specifications
Maximum Shut-off Head: 18 feet
Maximum Flow: 16 gpm
Maximum Operating Pressure: 125 psi
(8.6 bar)
Maximum Water Temp: 230°F (110°C)
Minimum Water Temp: 36°F (2°C)
Electrical specifications:
Voltage: 120V, 60 Hz
Single phase
Operating Power: 4W - 44W
Max. AMP Rating: 0.54
Equipped with a cast iron casing
and should be used for closed
loop systems only
Taco circulator pumps are
for indoor use only
Acceptable for use with water or
maximum of 50% water/glycol solution
Pump Dimensions & Weights
Electrical Data
Model Volts Hz Ph Max.Amps Max. Watts RPM
All Models
120 60 1 .54 44 1590 - 4830
Motor
Type
ECM, Permanent Magnet, Thermally Protected
Materials of Construction:
Casing: ...............................Cast Iron
Stator Housing: .............Composite
Cartridge: ..........................Composite
Impeller: ............................Composite
Shaft: ....................................Ceramic
Bearings: ............................Carbon
Thrust Bearing: ..............Ceramic
O-Ring & Gaskets: ........EPDM
Integral Flow Check (IFC
®
):
Body, Plunger .......Acetal
O-ring Seal .............EPDM
Spring ........................Stainless Steel
Applications
The VR1816 circulator is a variable speed, high-efficiency wet rotor circulator
with an ECM permanent magnet motor. Operating modes include infinitely
variable fixed speed to fine tune any zone, self-adjusting constant pressure for
zone valve applications and self-adjusting proportional pressure for panel
radiators with thermostatic radiator valves. The VR1816 is not suitable for
chilled water or open loop potable water applications.
Mounting Positions
Flange Orientation
Standard (S)
Part
Number
Flange
Code
A B C D F G Ship Wt.
in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
VR1816-HYI-FC2A00 S 6 152 4-1/8 104 3-3/16 80 3-1/4 82 5 126 6-3/8 161 5.8 2.6
VR1816-HYI-4C2A00 U 6 152 4-1/8 104 3-3/16 80 3-1/4 82 5-1/8 130 6-3/8 161 6 2.7
Universal (U)