Submittal Data Information
Model 0010-IFC
®
Cartridge Circulator
Submittal Data # 101-085
Supersedes: 08/02/11
Effective: 06/03/13
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
Application
The 0010-IFC with an Integral Flow Check is designed to reduce installation costs
when zoning with 00®circulators. Ideal for residential or light commercial hydronic
or radiant heating, hydro-air fan coils, indirect water heaters or domestic water
recirculation systems. By locating the IFC inside the pump casing, a separate
in-line flow check is eliminated, reducing installation costs. The reduced pressure
drop of the IFC increases the flow performance over in-line check valves. Both the
IFC and cartridge are easily accessed for service instead of replacing the entire unit.
Available in Cast Iron or Stainless Steel construction.
Features
• Integral Flow Check (IFC
®
)
Prevents gravity flow
Eliminates separate in-line flow check
Reduces installed cost, easy to service
Improved performance vs.
In-line flow checks
• Unique replaceable cartridge-
Field serviceable
• Unmatched reliability - Maintenance free
• Quiet, efficient operation
• Direct drive - Low power consumption
• Self lubricating, No mechanical seal
• Standard high capacity output -
Compact design
• Wide range of applications
• Cast Iron or Stainless Steel construction,
Flanged connection
s
Materials of Construction
Casing (Volute): Cast Iron or Stainless Steel
Integral Flow Check:
Body, Plunger ............Acetal
O-ring, Seals ...............EPDM
Spring ............................St. Steel
Stator Housing: ...............Aluminum
Cartridge: ............................ Stainless Steel
Impeller: ..............................Non-Metallic
Shaft: ......................................Ceramic
Bearings: ..............................Carbon
O-Ring & Gaskets: ..........EPDM
Model Nomenclature
F – Cast Iron, Flanged
SF – Stainless Steel, Flanged
IFC – Integral Flow Check
Performance Data
Max. Flow: 30 GPM
Max. Head: 9 Feet
Min. Fluid Temperature: 40˚F (4˚C)
Max. Fluid Temperature: 230°F (110˚C)
Max. Working Pressure: 125 psi
Connection Sizes:
3/4”, 1”, 1-1/4”, 1-1/2” Flanged
FLOW-GPM
0246810 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
TOTAL HEAD-FEET
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
FLOW-M3/H
0.0 0.51.0 1.52.0 2.53.0 3.54.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.510.0
TOTAL HEAD-METERS
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
11.0
009-IFC
0010-IFC
0011-IFC
0012-IFC
0013-IFC
0014-IFC
INTEGRAL FLOWCHECK (IFC
®
) MODELS
Performance Field - 60Hz
Mounting Positions
Standard Optional
OK if over 20 psi
Flange Orientation
Pump Dimensions & Weights
Electrical Data
Models Casing
A B C D F G
Ship Wt.
in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
0010-F3-1 IFC Cast Iron
7-1/4
184 5-5/16 135
3-3/16
81
3-15/16
84 5-3/8 137 6-3/8 162 10 4.5
0010-SF3-IFC St. Steel
7-1/4
184 5-5/16 135
3-3/16
81
3-15/16
84 5-1/8 137 6-3/8 162 9 4.0
Model
Volts Hz Ph Amps RPM
HP
0010-F3-1 IFC
115
60 1 1.10 3250 1/8
0010-SF3-IFC
115
60 1 1.17 3250 1/8
Motor
Type
Permanent Split Capacitor
Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Low-Lead Compliant
Certifications & Listings
FOR INDOOR USE ONLY