Install Instructions

ELECTRICAL SUPPLY
A 110V electrical supply outlet is required to power the TacoGenie unit. If an outlet is not
available, install a 110V outlet in accordance with all local electrical codes. Caution: Do
not plug in the TacoGenie until all plumbing and wiring connections are completed
and water supply is turned on. Running the circulating pump without water may dam-
age internal components and void warranty.
PLUMBING INSTRUCTIONS USING USK- PLUMBING ADAPTER KIT
1. Turn off the house water supply at the main shut-off valve.
2. Open hot and cold faucets at the fixture chosen for installation. This will relieve water
pressure from the hot and cold water lines.
3. Remove the hot and cold shut-off valve angle stops from the
1
2
" copper pipes located
below the sink. Be sure to use a catch basin to drain water from hot and cold lines.
Warning: To prevent scalding, use caution when removing valve on hot water line.
For ease of installation, leave the existing compression ring and nut from the angle
stops on the hot and cold water lines.
4. Remove the compression ring and nut from the adapter tees provided and slide on to
opposite straight copper end. Attach the existing nut and ring to the threaded end of
the tee and tighten firmly.
5. Connect the shut-off valves to the new compression ring and nut and tighten firmly.
6. Assemble shut-off
flanges to 0011 pump
as shown in Figure 3
and tighten firmly.
7. Attach the stainless
steel flex lines to the
3
4
"
threaded connection on
the tees and the
3
4
"
threaded connections
on the pump shut-off
flanges. Teflon tape is
recommended for all
threaded fittings.
INSTALLATION FOR THE CF-SERIES TACO GENIE
MODEL 0011-CF-USK
The two custom adapter “T”s are designed to simplify your
installation to
1
2
" copper hot and cold supply lines. If you
have plumbing other than as shown in these instructions,
additional fittings may be required. Consult a plumbing pro-
fessional.
1. Turn off water supply and
remove angle stops.
2. Install tees and attach angle
stops.