Product Overview

Performance Data
Flow Range:
0 - 12.5 GPM
Head Range:
0 - 15 Feet
Connection Sizes:
3/4, 1, 1-1/4, 1-1/2 Flanged
or 3/4 Sweat
Application
The 008-IFC
®
with an Integral Flow Check (IFC
®
) is designed to reduce installation costs when
zoning with “00
®
” circulators on Hydronic or Radiant heating, Hydro-Air Fan Coils or closed loop
solar heating systems. By locating the patented IFC
®
inside the pump casing, a separate in-line flow
check is eliminated, reducing installation costs. The reduced pressure drop of the IFC
®
, increases the
008 flow performance up to 260% over in-line check valves. Both the IFC
®
and cartridge are easily
accessed for service instead of replacing the entire unit. The 008-Z-IFC
®
combines the circulator,
flow-check and patented Priority Zoning control with built-in transformer, relay and priority switch
in one complete, compact package to make it ideal for zoning. Available in Cast Iron or Bronze
construction.
Model Nomenclature
F – Cast Iron, Flanged
Z Zoning Circulator
BC – Bronze, Sweat, Panel Mount
IFC
®
– Integral Flow Check
Model 008-IFC
®
Cartridge Circulator
13.
Model Volts Hz Ph Amps RPM HP
All 008 Models 115 60 1 .79 3250 1/25
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Pump Dimensions & Weights
A B C D E F Ship Wt.
Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
008-F6-IFC
Cast Iron 7 178 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
008-ZF6-IFC
Cast Iron 7 178 4-1/2 114 3-3/16 81 3-5/8 92 5-9/16 143 6-3/8 162 9 4.0
008-BC6-IFC
Bronze 6-1/2 165 4-9/16 116 3-3/16 81 2-15/16 75 4-11/16 119 6-3/8 162 9 4.0