Product Overview

Model Nomenclature
F – Cast Iron, Flanged
BF – Bronze, Flanged
Variations:
Z Zoning Circulator
J Bronze Cartridge with Cast Iron Casing
A
B
F
D
G
C
Pump Dimensions & Weights
A B C D F G Ship Wt.
Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
005-F2 Cast Iron 5-5/8 143 4 102 3-3/16 81 2-15/16 75 4-3/4 121 6-3/8 162 8.0 3.6
005-BF2 Bronze 5-5/8 143 4 102 3-3/16 81 2-15/16 75 4-3/4 121 6-3/8 162 8.0 3.6
Performance Data
Flow Range: 0 18 GPM
Head Range: 0 – 9.5 Feet
Connection Sizes: 3/4", 1", 1-1/4", 1-1/2" Flanged
Application
The Taco 005 is designed for a wide range of Residential/Light Commercial water circulating
applications. Typical uses include Hydronic heating, add a zone additions, Zoning with circulators,
Chilled Water cooling and Domestic Water Systems. Available in Cast Iron or Bronze construc-
tion with universal flange to flange dimensions. The unique replaceable cartridge contains all of the
moving parts and allows for easy service, instead of replacing the entire circulator. Compact,
direct-drive, low power consumption design is ideal for high efficiency jobs.
Model Nomenclature
F – Cast Iron, Flanged
BF – Bronze, Flanged
Variations:
Z Zoning Circulator
J Bronze Cartridge with Cast Iron Casing
A
B
F
D
G
C
Performance Data
Flow Range: 0 20 GPM
Head Range: 0 – 11 Feet
Connection Sizes: 3/4", 1", 1-1/4", 1-1/2" Flanged
Application
The Taco 007 is a cartridge style, maintenance free, wet-rotor, in-line, single stage circulator. It is
designed for quiet operation in Hydronic Heating, Radiant Heating, Hydro-Air Fan Coils, Indirect
Water Heating, Chilled Water cooling, and Domestic Water Systems. Available in Cast Iron or
Bronze construction with universal flange to flange dimensions. The unique replaceable cartridge
contains all of the moving parts and allows for easy service, instead of replacing the entire
circulator. Ideal for a wide range of applications.
Model 005 Cartridge CirculatorModel 005 Cartridge Circulator
Model 007 Cartridge CirculatorModel 007 Cartridge Circulator
Pump Dimensions & Weights
A B C D F G Ship Wt.
Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
007-F5 Cast Iron 6-1/8 156 4-1/2 114 3-3/16 81 2-15/16 75 4-3/4 121 6-3/8 162 8.0 3.6
007-BF5 Bronze 6-1/8 156 4-1/2 114 3-3/16 81 2-15/16 75 4-3/4 121 6-3/8 162 8.0 3.6
5.
Model Volts Hz Ph Amps RPM HP
005-F2 115 60 1 .53 3250 1/35
005-BF2 115 60 1 .54 3250 1/35
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Model Volts Hz Ph Amps RPM HP
007-F5 115 60 1 .70 3250 1/25
007-BF5 115 60 1 .76 3250 1/25
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data