Brochure

Model 006 Plumb n’ Plug
®
Model Nomenclature
B Bronze, Sweat
BC Panel Mount Tappings
BT Bronze, 3/4” FNPT
BC-1 Bronze, Union Connection
PNP Plumb n’ Plug
®
Prewired Timer & Cord
Performance Data
Flow Range: 0 6 GPM
Head Range: 0 – 5 Feet
Connection Sizes: 1/2, 3/4" Swt; 3/4 NPT; Union
Model 003 Plumb n’ Plug
®
Application
The Taco 003-PNP periodically re-circulates hot water through the domestic piping system to decrease the
delivery time to outlet fixtures and reduce wasted water. Typical timer programming will cycle the Plumb n’
Plug during high peak usage periods such as early morning or early evening. An optional Aquastat is available for
constant circulation applications to maintain temperature between 95°F and 115°F. The 003-PNP is ideal for
recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion, corro-
sion and noise in system piping. Use the 003 for systems up to 200 total feet (supply and return) of 3/4" pipe.
Installation of Isolation Valves, Pipe Insulation and Flow Check valves are recommended.
Application
The Taco 006-PNP periodically re-circulates hot water through the domestic piping system to decrease
the delivery time to outlet fixtures and reduce wasted water. Typical timer programming will cycle the
Plumb n’ Plug during high peak usage periods such as early morning or early evening. An optional Aquastat
is available for constant circulation applications to maintain temperature between 95°F and 115°F. The
Taco 006-PNP is designed for systems using 200-400 feet of 3/4" pipe. Installation of Isolation Valves, Pipe
Insulation and Flow Check valves are recommended.
Model Volts Hz Ph Amps RPM HP
006-PNP 115 60 1 .52 3250 1/40
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Model Nomenclature
B Bronze, Sweat
BC Panel Mount Tappings
BT Bronze, 3/4” FNPT
BC-1 Bronze, Union Connection
PNP Plumb n’ Plug
®
Prewired Timer & Cord
Performance Data
Flow Range: 0 10 GPM
Head Range: 0 – 9 Feet
Connection Sizes: 1/2, 3/4" Swt; 3/4 NPT; Union
Pump Dimensions & Weights
A B C D E F Ship Wt.
Model Connection in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
003-BC4-PNP 1/2” Swt 7-1/4 184 1-15/16 49 2-1/8 54 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
003-B4-PNP 3/4” Swt 7-1/4 184 1-15/16 49 2-3/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
003-BT4-PNP 3/4” FNPT 7-1/4 184 1-15/16 49 2 51 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
003-BC4-1PNP Union 7-1/4 184 1-15/16 49 2-31/32 76 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
003-BC4-3PNP 1/2” Swt 8-1/8 205 1-15/16 49 2-13/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
003-BC4-2PNP 3/4” Swt 8-1/8 205 1-15/16 49 2-13/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
PNP Models with Integral Flow Check (IFC®)
Pump Dimensions & Weight
A B C D E F Ship Wt.
Model Connection in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
006-BC4-PNP 1/2” Swt 7-1/4 184 1-15/16 49 2-1/8 54 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
006-B4-PNP 3/4” Swt 7-1/4 184 1-15/16 49 2-3/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
006-BT4-PNP 3/4” FNPT 7-1/4 184 1-15/16 49 2 51 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
006-BC4-1PNP Union 7-1/4 184 1-15/16 49 2-31/32 76 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
006-BC7-1PNP 1/2” Swt 8-1/8 205 1-15/16 49 2-13/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
006-BC7-PNP 3/4” Swt 8-1/8 205 1-15/16 49 2-13/16 56 3-1/16 78 5-1/4 134 3-5/16 84 6.0 2.7
PNP Models with Integral Flow Check (IFC®)
10.
Model Volts Hz Ph Amps RPM HP
003-PNP 115 60 1 .43 3250 1/40
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data