Brochure

A B C D E F Ship Wt.
Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
007-F5-IFC Cast Iron 7 178 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
007-ZF5-IFC Cast Iron 7 178 4-1/2 114 3-3/16 81 3-5/8 92 5-9/16 143 6-3/8 162 9 4.0
Model 007-IFC
®
Cartridge Circulator
Application
The Taco 007-IFC
®
with an Integral Flow Check (IFC
®
) is designed to reduce installation costs when
zoning with “00
®
circulators on Hydronic or Radiant heating, Hydro-Air Fan Coils or Indirect
water heaters. By locating the IFC
®
inside the pump casing, a separate in-line flow check is elimi-
nated, reducing installation costs. The reduced pressure drop of the IFC
®
, increases the 007 flow
performance by up to 240% over in-line check valves. Both the IFC
®
and the replaceable cartridge
are easily accessed for service instead of replacing the entire unit. The 007Z-IFC
®
combines the
circulator, flow-check and patented Priority Zoning control with built-in transformer, relay and
priority switch in one complete, compact package to make it ideal for zoning. Available in Cast Iron
construction with flanged connections.
Pump Dimensions & Weights
Model Volts Hz Ph Amps RPM HP
All 007 Models 115 60 1 .71 3250 1/25
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Performance Data
Flow Range: 0 – 12.5 GPM
Head Range: 0 – 11 Feet
Connection Sizes: 3/4, 1, 1-1/4, 1-1/2 Flanged
Model Nomenclature
F Cast Iron, Flanged
Z Zoning Circulator
IFC
®
Integral Flow Check
Model 005-IFC
®
Cartridge Circulator
Application
The Taco 005-IFC
®
with an Integral Flow Check (IFC
®
) is designed to reduce installation costs when
zoning with “00
®
circulators on Hydronic or Radiant heating, Hydro-Air Fan Coils or Indirect
water heaters. By locating the patented IFC
®
inside the pump casing, a separate in-line flow check
is eliminated, reducing installation costs. The reduced pressure drop of the IFC
®
, increases the
005 flow performance up to 240% over in-line check valves. Both the IFC
®
and cartridge are easily
accessed for service instead of replacing the entire unit. The 005-Z-IFC
®
combines the circulator,
flow-check and patented Priority Zoning control with built-in transformer, relay and priority switch
in one complete, compact package to make it ideal for zoning. Available in Cast Iron construction
with flanged connections.
A B C D E F Ship Wt.
Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
005-F2-IFC Cast Iron 6-5/8 168 4-1/8 105 3-3/16 81 2-15/16 75 5 127 6-3/8 162 8 3.6
005-ZF2-IFC Cast Iron 6-5/8 168 4-1/8 105 3-3/16 81 3-5/8 92 5-9/16 143 6-3/8 162 8 3.6
Pump Dimensions & Weights
Model Volts Hz Ph Amps RPM HP
005-F2-IFC 115 60 1 .52 3250 1/35
005-ZF2-IFC 115 60 1 .52 3250 1/35
Motor Permanent Split Capacitor
Type Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Performance Data
Flow Range: 0 - 11.5 GPM
Head Range: 0 - 10 Feet
Connection Sizes: 3/4, 1”, 1-1/4”, 1-1/2 Flanged
Model Nomenclature
F Cast Iron, Flanged
Z Zoning Circulator
IFC
®
– Integral Flow Check
12.