Product Overview

Submittal Data Information
Model 0013-IFC
®
Cartridge Circulator
Submittal Data # 101-086
Supersedes: 08/07/07
Effective: 03/30/10
Application
The 0013-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00
®
circulators on high head / high flow hydronic or radiant heating, hydro-air fan coils or heat exchangers
and geothermal systems. By locating the removable, spring-loaded IFC inside the pump casing, a
separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the
IFC, increases the 0013 flow performance over in-line check valves. Both the IFC and cartridge are
easily accessed for service instead of replacing the entire unit.
FLOW-GPM
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
TOTAL HEAD-FEET
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
FLOW-M3/H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
TOTAL HEAD-METERS
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
11.0
009-IFC
0010-IFC
0011-IFC
0012-IFC
0013-IFC
0014-IFC
INTEGRAL FLOWCHECK (IFC
®
) MODELS
Mounting Positions
Standard Optional
OK if over 20 psi
Flange Orientation
Features
• IntegralFlowCheck(IFC
®
)
Prevents gravity flow
Eliminates separate in-line flow check
Reduces installed cost, easy to service
Improved performance vs. In-line flow checks
• Uniquereplaceablecartridge-Fieldserviceable
• Unmatchedreliability-Maintenancefree
• Quiet,efficientoperation
• Directdrive-Lowpowerconsumption
• Selflubricating,Nomechanicalseal
• Standardhighcapacityoutput-Compactdesign
• Widerangeofapplications
• CastIronorStainlessSteelconstruction,Flanged
Materials of Construction
Casing(Volute): CastIronorStainlessSteel
Integral Flow Check:
Body, Plunger ............... Acetal
O-ring Seals ................. EPDM 
Spring ............................ Stainless Steel
Stator Housing: Aluminum
Cartridge: Stainless Steel
Impeller: Non-Metallic
Shaft: Ceramic
Bearings: Carbon
O-Ring&Gaskets:EPDM
Model Nomenclature
F Cast Iron, Flanged
SF –Stainless Steel, Flanged
IFC Integral Flow Check
Variations:
J Bronze Cartridge with Cast Iron Casing
Performance Data
FlowRange:0-33GPM
Head Range: 0 - 32 Feet
MinimumFluidTemperature:40˚F(4˚C)
MaximumFluidTemperature:230°F(110˚C)
MaximumWorkingPressure:125psi
ConnectionSizes:3/4”,1”,1-1/4”,1-1/2”Flanged
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
Model Volts Hz Ph Amps RPM HP
AllModels
MotorPermanentSplitCapacitor
Type Impedance Protected
Motor
Options
220/50/1,220/60/1,230/60/1,100/110/50/60/1
Electrical Data
1156012.032501/6
Performance Field - 60Hz
Pump Dimensions & Weights
Cast Iron
St.Steel
ModelCasing
lbs. Kg
ShipWt.
in. mm
G
in. mm
F
in. mm
D
in. mm
C
in. mm
B
in. mm
A
0013-F3-1 IFC
0013-SF3-IFC
7-1/2
7-1/2
191
191
6-3/8
6-3/8
162
162
3-1/2
3-1/2
89
89
3-7/8
3-7/8
98
98
6
6
152
152
6-1/2
6-1/2
165
165
12.5
11.5
5.7
5.2
A
B
F
D
G
C
FOR INDOOR USE ONLY
NSF®.25%Lead
Complies with California Health and Safety
CodeSection116875/AB1953
andVermontAct193