Submittal Sheet

101-067
Model 006-IFC
®
Cartridge Circulator
Effective: June 6, 2011 Supersedes: April 15, 2006
Submittal Data Information
Job: Engineer:
Contractor:
Rep:
ITEM NO. MODEL NO. IMP. DIA. G.P.M. HEAD/FT. H.P. ELEC. CHAR.
A B C D E F Ship Wt.
Model
Conn
in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
006-BC7-1IFC 1/2" Swt 6 152 4-7/8 124 2-3/16 56 2-15/16 75 3-5/16 84 4-3/8 111 6.0 2.7
006-BC7-IFC 3/4" Swt 6 152 4-7/8 124 2-3/16 56 2-15/16 75 3-5/16 84 4-3/8 111 6.0 2.7
006-SC7-IFC Union 6 152 4-7/8 124 2-31/32 76 2-15/16 75 3-5/16 84 5-15/16 151 6.0 2.7
FLOW-GPM
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
TOTAL HEAD-FEET
0
2
4
6
8
10
12
14
16
FLOW-M3/H
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
TOTAL HEAD-METERS
0.0
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
003B-IFC
005-IFC
006-IFC
006B-IFC
007-IFC
008-IFC
008B-IFC
INTEGRAL FLOWCHECK (IFC
®
) MODELS
Performance Field - 60 Hz
Application
s$OMESTIC(OT7ATER2ECIRCULATION s7ATER3OURCE(EAT0UMPS
s(YDRO!IR&AN#OILS s0OTABLE7ATER3YSTEMS
s(EAT2ECOVERY5NITS
The 006-IFC with an Integral Flow Check (IFC
®
) is designed for the circulation of hot or chilled
fresh water in open or closed loop applications. The IFC feature simplifies piping, eliminates
separate in-line flow check, reduces installation costs and improves system performance. With its
patented location at the impeller inlet, the IFC is easy to service without removing the entire unit
from system piping. The unique, replaceable cartridge contains all of the moving parts and allows
for easy service instead of replacing the entire circulator.
Pump Dimensions & Weights
Mounting Positions
Standard
Optional
OK if over
20 psi
-ODEL6OLTS(Z0H!MPS20-(0
006 All Models 115 60 1 .52 3250 1/40
Motor Type 0ERMANENT3PLIT#APACITOR)MPEDANCE0ROTECTED
Motor Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data
Submittal Data Information
Model 006-IFC
®
Cartridge Circulator
Submittal Data # 101-067
Supersedes: 04/15/06
Effective: 06/01/11
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
Features
s)NTEGRAL&LOW#HECK)&#
®
0ATENT
0REVENTSGRAVITYFLOWREVERSEFLOW
Eliminates separate in-line flow check
2EDUCESINSTALLEDCOST
Improves system performance
Easy to service
s5NIQUEREPLACEABLECARTRIDGEFIELDSERVICEABLE
s5NMATCHEDRELIABILITY-AINTENANCEFREE
s1UIETEFFICIENTOPERATION
s3ELFLUBRICATING.OMECHANICALSEAL
s7IDE2ANGEOFAPPLICATIONS
s"RONZE#ONSTRUCTIONWITH3WEAT
Connections or Stainless Steel Union Connections
Materials of Construction
#ASING6OLUTE "RONZEOR3TAINLESS3TEEL
)NTEGRAL&LOW#HECK "ODY0LUNGER
.....
Acetal
O-ring Seals
.......
%0$-
Spring
............................
Stainless Steel
3TATOR(OUSING 3TEEL
Cartridge: Stainless Steel
)MPELLER .ON-ETALLIC
Shaft: Ceramic
Bearings: Carbon
/2ING'ASKETS %0$-#HLORINE2ESISTANT
Model Nomenclature
"#"RONZE3WEAT#ONNECTIONS0ANEL-OUNT4APPINGS
SC - Stainless Steel, Union Connection,
0ANEL-OUNT4APPINGS
IFC - Integral Flow Check
Performance Data
&LOW2ANGEn'0-
(EAD2ANGEn&EET
Minimum Fluid Temperature: 40˚F (4˚C)
Maximum Fluid Temperature: 220˚F (104˚C)
-AXIMUM7ORKING0RESSUREPSI
FOR INDOOR USE ONLY
.3&n .25% Lead
#OMPLIESWITH#ALIFORNIA(EALTHAND3AFETY
#ODE3ECTION!"
AND6ERMONT!CT
TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360
TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436
Printed in USA
Copyright 2011
TACO, Inc.

Summary of content (1 pages)