Submittal Sheet

101-078
Model 008-IFC
®
Cartridge Circulator
Effective: June 17, 2010 Supersedes: October 17, 2008
Submittal Data Information
Job: Engineer:
Contractor:
Rep:
ITEM NO. MODEL NO. IMP. DIA. G.P.M. HEAD/FT. H.P. ELEC. CHAR.
Do it Once. Do it Right.
®
TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360
TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436
Visit our website at: www.taco-hvac.com
Printed in USA
Copyright 2010
TACO, Inc.
Submittal Data Information
Model 008-IFC Cartridge Circulator
Submittal Data # 101-078
Supersedes: 10/17/08
Effective: 06/17/10
Application
s(YDRONIC(EATING#OOLING s(YDRO!IR&AN#OILS
s2ADIANT s$OMESTIC7ATER2ECIRCULATION"RONZE3TAINLESS3TEEL
s)NDIRECT7ATER(EATERS
The 008-IFC is designed to simplify piping, reduce installation costs and improve system performance
WHENZONINGWITH
®
CIRCULATORS"YLOCATINGTHE)&#INSIDETHEPUMPASEPARATEINLINEFLOWCHECK
is eliminated. The low pressure drop of the IFC increases flow performance vs. in-line flow checks.
"OTHTHE)&#ANDTHECARTRIDGEAREEASILYACCESSEDFORSERVICE
Performance Field - 60Hz
Mounting Positions
Standard Optional
OK if over 20 psi
Features
s)NTEGRAL&LOW#HECK)&#
®
Simplifies piping
Prevents gravity flow and reverse flow
Eliminates separate in-line flow check
2EDUCESINSTALLEDCOST
Improves system performance
Easy to service
s5NIQUEREPLACEABLECARTRIDGE&IELDSERVICEABLE
s5NMATCHEDRELIABILITY-AINTENANCEFREE
s1UIETEFFICIENTOPERATION
s3ELFLUBRICATING.OMECHANICALSEAL
s7IDERANGEOFAPPLICATIONS
s#AST)RON"RONZEOR3TAINLESS3TEELCONSTRUCTION
s&LANGEDOR3WEATCONNECTIONS
Materials of Construction
#ASING6OLUTE #AST)RON"RONZEOR
304 Stainless Steel
)NTEGRAL&LOW#HECK)&#
®

"ODY0LUNGER!CETAL
/RING3EALS%0$-
Spring.................Stainless Steel
3TATOR(OUSING 3TEEL
Cartridge: Stainless Steel
)MPELLER .ON-ETALLIC
Shaft: Ceramic
"EARINGS #ARBON
/2ING'ASKETS%0$-
Model Nomenclature
F Cast Iron, Flanged
SF Stainless Steel, Flanged
"#n"RONZE3WEAT0ANEL-OUNT
IFC Integral Flow Check
Variations:
Z Zoning Circulator
62
6ARIABLE3PEED/UTDOOR2ESET
VS
Variable Speed Set Point
VV
Variable Speed Variable Voltage
*n"RONZE#ARTRIDGEWITH#AST)RON#ASING
Performance Data
&LOW2ANGE'0-
(EAD2ANGE&EET
-INIMUM&LUID4EMPERATURE&#
-AXIMUM&LUID4EMPERATUREª&#
-AXIMUM7ORKING0RESSUREPSI
#ONNECTION3IZESvvvv&LANGED
ORv3WEAT
FOR INDOOR USE ONLY
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
! " # $ % & 3HIP7T
-ODEL #ASING IN MM IN MM IN MM IN MM IN MM IN MM LBS +G
&)&##AST)RON              
3&)&#33TEEL              
3&)&#33TEEL              
"#)&#"RONZE              
Pump Dimensions & Weights
-ODEL 6OLTS (Z 0H !MPS 20- (0
Cast Iron
     
"RONZE33
     
-OTOR0ERMANENT3PLIT#APACITOR
Type Impedance Protected
-OTOR
Options

Electrical Data
Standard
Flange Orientation
Optional
008-SF6- IFC Only
.3&n,EAD
#OMPLIESWITH#ALIFORNIA(EALTHAND3AFETY
#ODE3ECTION!"
AND6ERMONT!CT
NSF® ≤ .25% Lead
Complies with California
Health and Safety
Code Section
116875 / AB1953
and Vermont Act 193