8. Plug the external temperature sensor provided into the “TEMP SEN-
SOR” receptacle on the side of the capacitor base. Attach the sensor
to the hot water supply pipe downstream of the pump using the black
zip-tie connector provided.
Once the system is filled and air is purged, plug in the SmartPlus
power cord.
NOTE: The temperature sensor must be installed and connected
in either “Pulse” or “Smart” mode.
NOTE: The SmartPlus must be installed and supported by the
circulation piping.
Hot Water Return Line (Option No. 2) - Install the SmartPlus on the
domestic hot water (DHW) return line pumping toward the DHW source.
The external sensor provided with the SmartPlus should be installed on
the DHW supply line. Refer to Figure 2.
1. Install the SmartPlus in-line on the DHW return line as shown in
Figure 2. Be sure the directional arrow on the casing is installed with
the arrow pointing toward the hot water source.
2. Follow steps 2 thruough 7 listed under the Hot Water Supply Line
(Option No. 1) section.
3. Plug the external temperature sensor provided into the “TEMP SEN-
SOR” receptacle on the side of the capacitor base. Attach the sensor
to the hot water supply pipe using the black zip-tie connector provided.
NOTE: The temperature sensor provided may not have enough
wire length to reach the DHW supply pipe with the SmartPlus
installed on the return line. In this case, standard low voltage
doorbell wire (not included) can be spliced into the sensor line
increasing the overall sensor wire length.
Once the system is filled and air is purged, plug in the SmartPlus
power cord.
NOTE: The temperature sensor must be installed and connected
in either “Pulse” or “Smart” mode.
NOTE: The SmartPlus must be installed and supported by the
circulation piping.
OTHER SPECIAL FEATURES OF THE SMARTPLUS:
1. Vacation Function - If no water usage is detected for 36 hours, the
pump will remain off until hot water usage is detected. Once detect-
ed, the pump will resume operation.
NOTE: If pump is set to “Smart” mode, the pump will operate in
“Pulse” mode for the first 7 days while recording usage patterns.
2. Exercise Function - While in vacation mode, the pump will come on
every 7 days and run for 10 seconds to prevent any corrosion or scale
buildup.
3. Power Outage - When power is restored, pump will revert to its mode
setting, either “Pulse” or “Smart”. If in “Smart” mode, previously
recorded data will not be saved and the pump will begin a new 7 day
usage learning cycle.
4. LED - The SmartPlus is provided with 3 LED’s located on the side of
the capacitor base.
Green LED Illuminated - Power On
Yellow LED Flashing - Pump in “Pulse” mode
Illuminated (not flashing) - Pump in “Smart” mode
Red LED LED off - Sensor is connected properly
LED flashes once every 5 seconds - Shorted sensor
LED flashes twice every 5 seconds - Open sensor
TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360.
TACO (Canadá), Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8. Telephone: 905/564-9422. FAX: 905/564-9436.
Visit our web site at: http://www.taco-hvac.com
Printed in USA
Copyright 2012
TACO, Inc.
Taco, Inc. will repair or replace without charge
(at the company’s option) any product or part
which is proven defective under normal use
within three (3) years from the date of start-up or
three (3) years and six (6) months from date of
shipment (whichever occurs first).
In order to obtain service under this warranty, it
is the responsibility of the purchaser to prompt-
ly notify the local Taco stocking distributor or
Taco in writing and promptly deliver the subject
product or part, delivery prepaid, to the stocking
distributor. For assistance on warranty returns,
the purchaser may either contact the local Taco
stocking distributor or Taco. If the subject prod-
uct or part contains no defect as covered in this
warranty, the purchaser will be billed for parts
and labor charges in effect at time of factory
examination and repair.
Any Taco product or part not installed or operat-
ed in conformity with Taco instructions or which
has been subject to misuse, misapplication, the
addition of petroleum-based fluids or certain
chemical additives to the systems, or other
abuse, will not be covered by this warranty.
If in doubt as to whether a particular substance
is suitable for use with a Taco product or part, or
for any application restrictions, consult the
applicable Taco instruction sheets or contact
Taco at [401-942-8000].
Taco reserves the right to provide replacement
products and parts which are substantially simi-
lar in design and functionally equivalent to the
defective product or part. Taco reserves the right
to make changes in details of design, construc-
tion, or arrangement of materials of its products
without notification.
TACO OFFERS THIS WARRANTY IN LIEU OF
ALL OTHER EXPRESS WARRANTIES. ANY
WARRANTY IMPLIED BY LAW INCLUDING
WARRANTIES OF MERCHANTABILITY OR
FITNESS IS IN EFFECT ONLY FOR THE DURA-
TION OF THE EXPRESS WARRANTY SET
FORTH IN THE FIRST PARAGRAPH ABOVE.
THE ABOVE WARRANTIES ARE IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR
STATUTORY, OR ANY OTHER WARRANTY
OBLIGATION ON THE PART OF TACO.
TACO WILL NOT BE LIABLE FOR ANY SPE-
CIAL, INCIDENTAL, INDIRECT OR CONSE-
QUENTIAL DAMAGES RESULTING FROM THE
USE OF ITS PRODUCTS OR ANY INCIDENTAL
COSTS OF REMOVING OR REPLACING
DEFECTIVE PRODUCTS.
This warranty gives the purchaser specific
rights, and the purchaser may have other rights
which vary from state to state. Some states do
not allow limitations on how long an implied
warranty lasts or on the exclusion of incidental
or consequential damages, so these limitations
or exclusions may not apply to you.
LIMITED WARRANTY STATEMENT
CAUTION: Do not plug in the SmartPlus power
cord until the system is filled with water and
purged of air.
W
ARNING: All local plumbing and electrical codes
should be followed when installing this product.
WARNING: Risk of electrical shock. This pump is
supplied with a grounding conductor and ground-
ing-type attachment plug. To reduce the risk of
shock, be certain that it is connected only to a
properly grounded grounding-type receptacle.