Submittal Sheet

3UBMITTAL$ATA
Supersedes: 10/15/03
Effective: 03/03/08
4ACO)NC#RANSTON3TREET#RANSTON2)&AX
4ACO#ANADA,TD/RDAN$RIVE-ISSISSAUGA/NTARIO,4"&AX
www.taco-hvac.com
Submittal Data Information
Heat Motor Zone Valves
Models
555
556
557
5101G
556G
557G
560
561
562
570
571
572
573
Kg.
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Connection
1/2" Sweat
3/4" Sweat
1" Sweat
3/4" Threaded
3/4" Sweat
1" Sweat
1/2" Sweat
3/4" Sweat
1" Sweat
1/2" Sweat
3/4" Sweat
1" Sweat
1 1/4" Sweat
Style
2-Way
2-Way
2-Way
2-Way
2-Way
2-Way
3-Way
3-Way
3-Way
2-Way
2-Way
2-Way
2-Way
in.
3 1/16"
3 3/8"
3 5/8"
3 3/8"
3 3/8"
3 5/8"
3 1/16"
3 3/8"
3 5/8"
3 1/16"
3 3/8"
3 5/8"
3 7/8"
mm.
78
86
92
86
86
92
78
86
92
78
86
92
98
in.
5 3/8"
5 3/8"
5 3/8"
5 3/8"
5 3/8"
5 3/8"
5 11/16"
5 7/8"
6"
4 13/16"
4 13/16"
4 13/16"
4 13/16"
mm.
136
136
136
136
136
136
144
149
152
122
122
122
122
in.
1 9/16"
1 9/16"
1 9/16"
1 9/16"
1 9/16"
1 9/16"
1 13/16"
2"
2 1/8"
15/16"
15/16"
15/16"
15/16"
mm.
40
40
40
40
40
40
46
51
54
24
24
24
24
in.
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
mm.
51
51
51
51
51
51
51
51
51
51
51
51
51
Lbs.
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
A
" C D 3HIP7T
$IMENSIONS7EIGHTS
Models
555
556
557
5101G
556G
557G
560
561
562
570
571
572
573
Stem / Seal
Bellows
Bellows
Bellows
O-Ring Gland
O-Ring Gland
O-Ring Gland
Bellows
Bellows
Bellows
Bellows
Bellows
Bellows
Bellows
Seat Assy.
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Silicone Bronze
Silicone Bronze
Silicone Bronze
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Brass / Eng. Polymer
Volts
24
24
24
24
24
24
24
24
24
24
24
24
24
Hz
60
60
60
60
60
60
60
60
60
60
60
60
60
Amps
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
.ORMAL&LOW
2ANGES'0-
1 - 4 1/2
4 1/2 - 6
6 - 10
4 1/2 - 6
4 1/2 - 6
6 - 10
1 - 4 1/2
4 1/2 - 6
6 - 10
1 - 4 1/2
4 1/2 - 6
6 - 10
10 - 16
Cv
4.2
6.1
7.0
6.1
6.1
7.0
4.2
6.1
7.0
4.2
6.1
7.0
7.2
%QUIV&T
of Pipe
10
20
60
20
20
60
10
20
60
10
20
60
130
-IN&LUID
4EMPª&
40°
40°
40°
40°
40°
40°
40°
40°
40°
40°
40°
40°
40°
-AX&LUID
4EMPª&
240°
240°
240°
240°
240°
240°
240°
240°
240°
240°
240°
240°
240°
-AX7ORKING
0RESSUREPSI
125
125
125
125
125
125
125
125
125
125
125
125
125
Pump Head
&TOF7ATER
150
150
150
150
150
150
65
65
65
65
65
65
65
"ODY
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Bronze
Electrical Performance Materials of Construction
100-3.2
Heat Motor Zone Valves
Effective: March 3, 2008 Supersedes: October 15, 2003
Submittal Data Information
Job: Engineer:
Contractor:
Rep:
ITEM NO. MODEL NO.
Do it Once. Do it Right.
®
TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360
TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436
Visit our website at: www.taco-hvac.com
Printed in USA
Copyright 2007
TACO, Inc.

Summary of content (1 pages)