Install Instructions

Once cycled through all three primary menus the keyboard
r
eturns to the locked position. If no button is pushed for 30
seconds the display goes blank and returns to the locked
position.
Note: If the FloodBreaker is attached to an external
power source, the display always remains active.
In the standard leak protection mode the system monitors the
water volume used without any interruption, the length of time
water is used without interruption as well as the flow rate.
Should one of the following criteria be exceeded, the device
suspects a leak, closes the valve and displays a shut-off
code.
1. Volume-based leak Message A3 is displayed if the
water volume used exceeds the set limit without inter-
ruption.
2. Flow rate Message A4 is displayed if 15.5 GPM is
exceeded for the set period of time.
3. Time-based leak Message A9 is displayed when con-
stant flow is detected over a time limit based on the fol-
lowing settings. To override the default time see section
6.3.
If you are not using an external power source, press any
button to activate the display. LE appears in the display
window. If vacation leak mode is activated UL appears in
the display instead.
1. Unlock the menu per previous instructions in section
4.1 (Figure 3); either LE or UL will be flashing on the dis-
play screen.
2. Press the button once and LE will be displayed
(Figure 4).
3. Press the button again to display the current leak
setting (Figure 5).
6
5. User Menu
5.1 Standard leak protection
LE Standard Protection Setting Default Time
Leak setting 1-4 2 hours
Leak setting 5-7 3 hours
Leak setting 8-11 4 hours
Leak setting 12 - 15 5 hours
Note: The valve will close if constant flow is detected once
the time limit is reached. This happens even if the water
volume has not reached the leak set point.
5.2 Setting the standard leak
protection
Note: The FloodBreaker is shipped with the Vacation Leak
Protection (UL) setting active. Vacation Leak Protection
w
ill override the Standard Leak Protection (LE) and must
be deactivated (See section 5.5) for the Standard Leak
Protection to be active.