Install Instructions

Instruction Sheet
IFSW1/W2 Industrial Flow Switch
Listings/Approvals:
UL Guide (NKPZ) for industrial control
equipment per UL Standard 508 Indus-
trial Control Equipment
UL Guide (MFHX) for heating/cooling
appliance switch per UL Standard 353
Limit Controls
CSA Class (321106) for industrial con-
trol equipment per CSA Standard
C22.2 No. 14-M Industrial Control
Equipment
CE Marked
Maximum Service Pressure: 250 PSI
Enclosure:
Die-cast grey powdercoat finish on cover.
Plated steel base.
Not for use in hazardous locations.
Contacts:
IFSW1: One SPDT (Form C) switch
IFSW2: Two sets of SPDT (Form C)
switches to provide versatility in wiring two
separate circuits.
15 Amps at 125/250VAC
.5 Amps at 125VDC
.25 Amps at 250VDC
Motor Ratings : 120VAC 240VAC
Horsepower : 1/8 1/4
AC F.L.A. : 3.8 2.9
AC L.R.A. : 22.8 17.4
Pilot Duty Rating :125VA 120/240VAC
Environmental Specifications:
Suitable for indoor or outdoor use with
factory installed gasket and die-cast hous-
ing.
NEMA 4 Rated Enclosure - use with appro-
priate conduit fitting.
Ambient Temperature Range:
32°F to 176°F (0°C to 80°C)
Media Temperature Range:
32°F to 250°F (0°C to 121°C)
Pipe Connections:
1" NPT Brass on models IFSxxB
1" NPT 316 Stainless Steel on models
IFSxxS
Conduit Entrance:
One opening for 1/2" conduit
Usage: For pipe sizes 1" - 8"
Caution: This device is not intended for appli-
cations in explosive environments.
GENERAL
The Model IFSW1/W2 Series is a flow switch
used in liquid flow lines carrying water or any
fluid not harmful to brass, stainless steel,
EPDM or fluorosilicone, and not classified as a
hazardous fluid.
This switch can serve as a way to start and
stop electrically operated equipment when a
flow or no flow condition occurs in a variety of
applications.
This device is designed for use only as an
operating control. Where an operating control
failure would result in personal injury and/or
loss of property, it is the responsibility of the
installer to add devices (safety, limit controls)
that protect against, or systems (alarm, super-
visory systems) that warn of control failure.
102-027
SUPERCEDES: 102-027 DATED May 8, 2003
# 5401111-REV F
EFFECTIVE: March 17, 2004

Summary of content (4 pages)