Submittal Sheet
Submittal Data Information
Viridian VR3452
301-2694
EFFECTIVE: July 20, 2015 SUPERSEDES: January 15, 2015
WEIGHT ____ PUMP/MOTOR
DIMENSIONS:
JOB ____________________________________________ ENGINEER ______________________________
CONTRACTOR ___________________________ REP _____________________________________
MODEL
NUMBER
FLANGE
SIZE
POWER
(HP)
DIMENSIONS — IN. (mm)
WEIGHT
LBS. (KG)
A B C D E F
VR3452-FC1A00 3/4 to 1
1
⁄
2
" 1/100 to 1/4 6–3/8 (162) 9–3/4 (247) 7–1/2 (190.5) 4 (102) 4–5/8 (117) 7 (177.8) 8.0 (3.6)
VR3452-FC1A01
(with comm module)
3/4 to 1
1
⁄
2
" 1/100 to 1/4 6–3/8 (162) 11 (279) 8–3/4 (222.25) 4 (102) 4–5/8 (117) 7 (177.8) 8.3 (3.8)
PUMP SPECIFICATIONS:
• Maximum Operating Pressure: 145 PSI (10 bar)
• Water Temperature Range: 14º – 230ºF (-10º – 110ºC)
• Ambient Operation Temperature Range: 32º – 104ºF
(0º – 40ºC). Ambient temperature should be 104ºF (40ºC)
or lower when fluid temperature exceeds 194ºF (90ºC).
• Minimum static inlet pressure at pump suction port
(PSI / bar) to avoid cavitation at fluid temperatures:
• Designed for closed loop heating and cooling systems
pumping water or a water/glycol mixture.
• For indoor use only - employer uniquement a l’interieur.
• Flanged in-line connections. Companion flanges not included.
Uses 3/4" to 1-1/2" Freedom Flanges - see cat#100-7.3,
005-0011 flanges.
MATERIALS OF CONSTRUCTION:
• Casing: Cast Iron cataphoresis coated
• Impeller: Engineered Polymer
• Shaft: Stainless Steel
• Bearing: Metal Impregnated Carbon
ELECTRICAL SPECIFICATIONS:
• Pump Ratings: 1 phase, 110 - 120V, 47-63Hz (VR3452-HY1)
1 phase, 200 - 240V, 47-63Hz (VR3452-HB1)
• Power Consumption: 1/4HP, 10-180W
• Rated Current: (1 phase, 115V) 0.1A to 2.5A
(1 phase, 230V) 0.1A to 1.65A
• Continuous Duty
• Built-in Startup circuit
FLUID
TEMPERATURES
(PSI / Bar)
112ºF (50ºC) 0.73/0.05
176ºF (80ºC) 5.8/0.4
230ºF (110ºC) 15.95/1.1
ITEM NO. MODEL NO. G.P.M. T.D.H. MAX HP ELEC. CHAR. H MAX SETTING % PROP SETTING