4.1.2 Electrical Safety Rules
The mains powers the L-SP2 so it is necessary to provide a differential protection and a
shutting-off device. Figure 3 below shows how to connect the L-SP2 pedestals to the mains.
Figure 3: Safety Electrical Installation
Micro
circuit
breaker
Differential
circuit
-
breaker
AC main line
+
Neutral
AC main
L-SP2
L-SP2
L-SP2
The power supply cable provided is of PVC type, H05VVF 0.75 mm² multi-stranded (14 AWG) and
complies with FEC60950 standard.
4.1.3 Network cable installation
The LSP2 Ethernet version is provided with an Ethernet cable mounted with a ferrite for LAN
cables. If the cable is to be changed, you will have to add a ferrite to this cable.
References:
Ethernet cable: Unshielded Ethernet cable, UTP-Cat5
Ferrite for LAN cable: Würth Electronik (Manufacturer ref: 742 7111)
This ferrite will have to be installed as follow (Figure 4):
Inside the electronic casing
Near the Moxa board
20mm maximum distance from the RJ45 connector.
The electrical installation must be carried on by qualified personnel only. Micro circuit breaker
and differential circuit-breaker ratings depend on country regulations in force.