User Manual

Library Security Pedestal 2
30/62 Revision 4.2 July 2008
For the Ethernet version, the first step is to allocate a unique IP address to each L-SP2.
This operation will allow identifying each L-SP2 on site before configuring them on the Ethernet
network.
Setting of L-SP2 IP addresses can be done in console mode using the HyperTerminal software via
the RS232 link on DB9 connector as shown in Figure 15.
Communication parameters are the followings:
Baud rate: 19200
Data bits: 8
Parity: none
Stop bit: 1
Figure 15: Configuration Connector
1. Once the communication parameters have been set, type any key to switch from Data
mode to Console mode.
2. Type 2 to select “Network settings” and then press Enter.
3. Type 1 to select “IP address” and then press Enter.
4. Use Backspace key to erase the current IP address, type the new IP address then press
Enter.
5. Return to Main menu, and select “Save/Restart” to memorise the configuration.
For more information regarding the IP addresses setting please see Moxa NE-4100 Series User’s
Manual available on
http://www.moxa.com.
Once all the IP addresses have been allocated, the L-SP2 plastic covers can be replaced.
By default the IP address is 169.254.0.100 (port 4001) (IPv4 Automatic Private IP
Addressing). Ask your network administrator to obtain a static IP address for each of the
pedestals connected to your local network.
Configuration
Port