User Manual

Configuration
July 2008 Revision 4.2 37/62
Once you have set the basic configuration check that all the slaves are well synchronized. To do
so, L-SP2 electronics unit green LEDs should flicker cyclically. If not, proceed to the advanced
configuration stage.
Database
Each time an item (with EAS/AFI activated) passes through the gates an entry is added to a local
database in L-SP2 memory. This entry holds the following information:
The date and time to which the theft was committed.
The chip type (C220/C320, C370, C370-L, ISO15693).
If selected, the memory data.
The database section shows the number of entries stored in L-SP2 memory in real-time.
Access Database
To access the database, click “Access Database”: Database is downloaded and the following
window is displayed:
Figure 19: Database
Click:
“Refresh” to re-download Database.
“Clear” to ERASE L-SP2 Database.
“Close” to close the window.
You can access the database from your own application using MedioSTX.dll and Java SDM.
Please refer to the Medio STX Windows DLL Programming Guide.
CAUTION: When this window is open EAS/AFI detection is automatically suspended. It is
resumed when the window is closed.