User Manual

Maintenance
July 2008 Revision 4.2 53/62
8 Maintenance
8.1 Servicing the Pedestals
No regular servicing or maintenance is required, except for keeping the covers clean, and
occasionally checking the integrity of the cover seals.
It is recommended that the pedestal unit be inspected at least once per year by an approved
TAGSYS technical representative.
Refer to section 1.2 “Care and Maintenance” for general maintenance information.
8.2 Servicing the Electronics Unit
- Fuse characteristics:
On AC mains: Schurter FST, 5X20mm, Time-Lag T, H, 250VAC, 500mA
On DC supply: Schurter SPT, 5X20mm, Time-Lag T, H, 300VDC, 2A
-How to change them:
1. Fuses are inside the electronic housing located at the bottom of the L-SP2 pedestal.
2. Unscrew the 9 screws from the cover located opposed side of the counter.
3. Unscrew the head fuse and replace the fuse inside the system fuse (please see figure
below)
WARNING: AC mains 110/220V. Be sure that there is no power supply current before
carrying on the connection operation. To do so, the micro circuit-breaker must be opened.
(Figure 3)
AC Main Fuse
DC Supply Fuse