User Manual

20/68 Revision 2.1 December 2009
4.1.2 Electrical Safety Rules
The L-SP3 is powered up via a Mains Supply IEC Cord.
A group of up to 5 Pedestals can be daisy chained and powered via a single IEC power
cord connected to a wall socket. The mains wall socket should provide at least 2 Ampere and be
protected by a differential circuit breaker limiting the current to 5 Ampere maximum.
Figure 3 here below shows how to connect the L-SP3 pedestals to the mains.
Figure 3: Safety Electrical Installation Using Power Cord
Wall
Socket
IEC Power Cord
LSP3 Pedestals Aisle
4.1.3 Network cable installation
The L-SP3 Pedestal delivery package does not include an Ethernet cable to connect to a Local
Area Network for remote operation. We recommend the use of a Shielded Ethernet cable, UTP-
Cat 5.
The electrical installation must be carried on by qualified personnel only.
For each country where installation takes place, an adequate IEC power
supply Cord must be used, fitting the local wall socket layout.