Steps to undergo:
1. Prepare a 2 wire cable of appropriate length and number of connectors to wire up each
pedestal. Use the 3.81 mm Push-On Green Plugs Vertical Cable Entry provided.
2. Connect all pedestals Synchronization to the Synchronization I/O as shown on Figure 11.
3. Set each pedestal to hardwire synchronization modifying the “Mode” in the “Synch” Section
of the “Advanced Configuration” tab of the L-SP3 Pedestal Configuration Tool.
4. Write down the MAC address of each pedestal. Use the test button in “Monitoring” tab to
locate it: the connected pedestal will ring and its display lit.
5. Power up the whole system (every pedestal must be powered up) and check that the
synchronization process works properly detecting a book in each passageway.
6. Put the cover panel back into place and secure it with the 4 screws