User's Guide

Draft
Transportable Mobile Repeater User’s Guide Basic Operation 13
© Copyright Tait International Limited March 2019
charging, press the recessed button located at the left of the Charge LED to
turn charging off and on.
A DC input cable is supplied with the transportable for connection to
external DC Supplies between 10 and 36 VDC.
Notice When the transportable is not in use, always switch the bat-
tery select switch to External DC/Battery Isolate.
2.4 LED Indication Details
2.4.1 Repeater
a. after the four power-up sequences
2.4.2 Status
This LED is only lit when an AC supply is connected.
2.4.3 Charge
This LED is only lit when an AC supply is connected.
LED Indication Details
Repeater Power green repeater power is on
All LEDs/Alarm flashing power up sequence is in progress
Alarm on repeater is in offline mode
Alarm flashing
a
an alarm condition needs to be cleared
Receive orange receiver is receiving
Transmit orange transmitter is keyed
LED Indication Details
Status green battery is fully charged or above 20%
charged
Status red, flashing battery is low
Status off battery has been disconnected due to
low voltage