Installation and Operation Manual
Table Of Contents
- Installation and Operation Manual
- Contents
- Preface
- 1 Description
- 2 General Safety and Regulatory Information
- 3 Operation
- 4 Connecting to the Base Station
- 4.1 PC Recommendations
- 4.2 Connecting Your PC to the Base Station
- 4.3 Working with the Web Interface
- 4.4 Basic Tasks
- 4.4.1 User Settings
- 4.4.2 Taking the Base Station Offline
- 4.4.3 Troubleshooting Alarms
- 4.4.4 Working with Configuration Files
- 4.4.5 Single or channel group base stations
- 4.4.6 Marshaling or transmit delay
- 4.4.7 Configuring Receive-Only Base Stations
- 4.4.8 Setting Up Custom Alarms
- 4.4.9 Uploading Firmware from the Base Station
- 4.4.10 Downloading Firmware from a Package Server
- 4.4.11 Activating New Firmware
- 4.4.12 Subaudible Signaling
- 4.4.13 SNMP Network Management
- 5 Installation
- 6 Maintenance
- 7 Troubleshooting
- Appendix A – Interface Pin Allocations
- Appendix B– Installing the Firmware Package
- Glossary
- Tait General Software License Agreement
70 Troubleshooting TB7300 Installation and Operation Manual
© Tait International Limited November 2019
7 Troubleshooting
Check that all front and rear connectors and cables are in place, and that
power switches are on. If problems persist, contact your regional Tait
office.
Notice The TB7300 cannot be serviced in the field. It must be
returned to your regional Tait office for repair.
Symptom Possible Cause Action
Alarm LED red and steady
(not flashing)
The base station is in
Offline mode
Use the web interface to put the base station in
Online mode
Alarm LED flashing One or more faults are
present
Use the web interface to identify the fault
Power LED off The rear panel fuse has
blown.
Check the fuse.
There is a problem with
the supply voltage.
Check the supply input voltage.
Desired feature is not
operating
Feature license missing Check that you have the necessary feature
licenses (refer to “Licences” on page 14 and the
Help)
Feature license present
but feature is not enabled
Use the web interface to enable the feature
Tx stuck on Tx and Rx frequencies are
the same
Reconfigure Tx and Rx with different frequencies
The base station appears
to make random
transmissions
CWID feature enabled No action: CWID transmissions are made
according to configuration settings
PA has low power Channel is configured to
low power
Use the web interface to check the power settings
PA may have suffered
partial damage
Return the base station to Tait for replacement.