Service Manual Part 1


 +8+
  
+8/8- 9&)
The mode or status of the radio is indicated by the behaviour of:
the monitor LEDs (ML1 and ML2) on the top side of the logic PCB
the radio control head LEDs.
Unless otherwise stated, the two monitor LEDs behave as in normal operation:
ML2 is off
ML1 flashes at a rate of 1Hz to indicate watchdog timer ‘kick’ activity
In normal trunked radio mode, ML2 flashes at a rate of several Hertz. This indicates
control channel hunt or codeword reception on a control channel.
A value in brackets { } with a mode/status description indicates that the radio sends an
error message via the serial port upon engaging that mode/status.
This table identifies display states for trunked radios, with non-trunked models for
comparison.
Mode/State T2010/T2015 T2020 T2030/T2035 T2040
CONFIG error
Monitor LEDs
flashing together.
Display shows
“CONF-ERR”
Monitor LEDs
flashing together.
Top & bottom row
LEDs flashing. C1
LED on (if fitted)
Monitor LEDs
flashing together.
Display shows
“CONF-ERR”
CONFIG register
programmed
Display shows
“CONF-PGM”
Display undefined Display shows
“CONF-PGM”
ROM or RAM test
failure
CTCSS output tog-
gling. Display
undefined
Tone output tog-
gling. Display
undefined
Tone output tog-
gling. LEDs unde-
fined
Tone output tog-
gling. Display
undefined
ESN checksum error
{X31}
(go to program
mode)
As for program
mode + CLR LED
flashing. T2035: dis-
play shows “-U1”
Display shows
“ESN-ERR”
Database checksum
error {X32}
(go to program
mode)
As for program
mode.
2010: all channel
LEDs on
2015: display shows
“00”
Display shows
“-PROG-”
Top row LEDs on
As for program
mode + DESP LED
flashing.
T2035: display
shows “-U2
Display shows
“-DATA-ERR-”
Top row LEDs on.
System error
{Enn}
Monitor LEDs
alternately flashing
“-ERROR nn” in
display (nn = error
mumber)
Monitor LEDs &
top row LEDs flash-
ing.
2 digit BCD error
number on bottom
rows.
T2035: display
flashes error
number
Monitor LEDs
alternately flashing.
“ERROR nn” in dis-
play (nn = error
mumber)
MOBD link left in &
CONFIG register OK
{X06}
Display error
shows
“MODB-ERR”
Top & bottom row
LEDs flashing + C2
LED on (if fitted)
Display shows
“MODB-ERR”
Logon with test link
in
{X07}
Top & bottom row
LEDs flashing + C3
LED on (if fitted)
Display shows
“TLINK-ERR”
Key/LED test failure
{X04}
LED flashing
shows error - all
LEDs to right &
below on