User's Manual Part 6


673) 
  
3 Tx/Rx Out Function
Connect a wire from S24 on the T2000-80 PCB to S609 on the logic PCB, as shown
in Figure 8.14.1.
4 External Channel Control (T2010 Only)
Connect the 2 BCD lines a shown in Figure 8.14.1.
5 Refer to Section 8.14.3, “Line Interface Options”, Section 8.14.6, “Applications”
and the circuit diagram before selecting the T2000-80 PCB linking options.
Set up the T2000-80, as described in Section 8.14.4, “T2000-80 Set-Up”.
6 Carefully fold the logic and T2000-80 PCBs back in position, guiding the D-range
connector through the hole provided in the T2000 chassis.
Secure using the three logic PCB retaining screws and the three M3x8 screws pro-
vided, and refit the top cover.
Plug the D-range assembly provided in the kit into the D-range connector (S21).
 Holes are provided in the T2000 chassis for the D-range plug locking screws.
Use the two black 4-40 Taptite screws provided in the kit to form the threads.