User's Manual

TB8100 Specifications Manual Power Management Unit Specifications 33
© Tait Electronics Ltd June 2004
4 Power Management Unit Specifications
This chapter provides specifications pertaining to the power management
unit (PMU) as a separate module.
The performance figures given in these specifications are applicable only to
equipment operating as an integral part of a TB8100 base station. These
performance figures are minimum figures, unless otherwise indicated, for
equipment operating at standard room temperature (+22°C to +28°C
[+71.6°F to +82.4°F]) and standard test voltages as follows:
AC module - 230VAC
DC module - 12VDC.
Where applicable, the test methods used to obtain these figures are those
described in the ETSI-EN specifications. You can obtain further details of
test methods and the conditions which apply for compliance testing in all
countries from Tait Electronics Ltd.
Product
Identification
TB8100 PMUs are identified by a product code printed on the label fixed
to the rear panel. The product codes are explained in the following table.
Product Code Model
TBA30A0-xxxx AC PMU - 88VAC to 264VAC input
TBA3001-xxxx DC PMU - 12VDC input
TBA30A1-xxxx AC and DC PMU - 88VAC to 264VAC input
12VDC input