User's Manual

36 Power Management Unit Specifications TB8100 Specifications Manual
© Tait Electronics Ltd June 2004
Output - AC and DC Modules
High Current Output for PA
Voltage
Current
Regulation
Ripple and Noise*
Ripple and Noise rms
Transient Response on 28V Loadstep**
*100MHz bandwidth
**10% to 100% loadstep
28V
14A maximum
±0.5%
50mV pp
10mV rms
2% overshoot and recover within 0.6ms
Low Current Output for Reciter
Voltage
Current
Regulation
Ripple and Noise*
Ripple and Noise rms
*100MHz bandwidth
28.6V
26.5V in hysteresis mode
1.2A maximum
±3.5%
50mV pp
10mV rms
Protection - PA Output
Overload
Short Circuit
Overvoltage
AC Module
DC Module
electronic current limit above 16A
hiccup mode, self-resetting
electronic shutdown latch (33.5V)
electronic hysteric control (33.5V)
Protection - Reciter Output
Short Circuit 2.5A self-resetting fuse
Optional 10W Standby Output - DC Module
Low Current Output for Reciter
Voltage
Current
Regulation
Ripple and Noise*
Ripple and Noise rms
*100MHz bandwidth
28.9V
0.3A maximum
±2.5%
50mV pp
10mV rms
Protection
Overload/Short Circuit electronic current limit