User's Manual

38 Power Management Unit Specifications TB8100 Specifications Manual
© Tait Electronics Ltd June 2004
DC Input*
Connector Type
Flexible Wire Size
Current Rating
*battery
M6 screw into threaded fitting on bus bar
2AWG for a length of 1.5m to 2m (5ft to 6.5ft)
(typical)**
50A
**the DC input leads should be of a suitable gauge to ensure
less than 0.2V drop at maximum load over the required length
of lead
DC Output - 28V High Current
Connector Type
Flexible Wire Size
Current Rating
Phoenix MVSTBR2.5HC/2-ST/5.08 female
11AWG
16A
DC Output - 28V Low Current
Connector Type
Flexible Wire Size
Current Rating
2x4-way Molex 43025-0800/crimp socket 43030-0001
female
20AWG
3A
DC Output - 12V Low Current/Battery Charger
Connector Type
Flexible Wire Size
Current Rating
2x4-way Molex 43025-0800/crimp socket 43030-0001
female
20AWG
2 x 3A (2 conductors in parallel)
Connections (Continued)
Compliance Standards
Where applicable, this equipment has been tested and approved to the following standards.
Safety BS EN 60950-1:2002
ANSI/UL Std. 60950 3rd edition
CAN/CSA-C22.2 No. 60950-00 3rd edition
AS/NZS 60950 and ACATS001
EMC ETSI EN 301 489 V1.4.1 (2002-08)
CFR 47 Part 15 Level B1
Environmental
Low Pressure (Altitude)
Humidity
Vibration
Shock
MIL-STD-810F 500.4 Proc 2
IEC60068-2-30
MIL-STD-810F 514.5 Proc 1
MIL-STD-810F 516.5 Proc 1