Datasheet

TS7800 Series
3-Terminal Fixed Positive Voltage Regulator
2/12 Version: A07
TS7805 Electrical Characteristics
(Vin=10V, Iout=500mA, 0
o
CTj125
o
C, Cin=0.33uF, Cout=0.1uF; unless otherwise specified.)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Tj=25
o
C
4.80
5
5.20
Output voltage
Vout
7.5VVin20V,
10mAIout1A, PD15W
4.75
5
5.25
V
7.5VVin25V
--
3
100
Line Regulation
REGline
Tj=25
o
C
8VVin12V
--
1
50
10mAIout1A
--
15
100
Load Regulation
REGload
Tj=25
o
C
250mAIout750mA
--
5
50
mV
Quiescent Current
Iq
Iout=0, Tj=25
o
C
--
4.2
8
7.5VVin25V
--
--
1.3
Quiescent Current Change
ΔIq
10mAIout1A
--
--
0.5
mA
Output Noise Voltage
Vn
10Hzf100KHz, Tj=25
o
C
--
40
--
µV
Ripple Rejection Ratio
RR
f=120Hz, 8VVin18V
62
78
--
dB
Voltage Drop
Vdrop
Iout=1.0A, Tj=25
o
C
--
2
--
V
Output Resistance
Rout
f=1KHz
--
17
--
mΩ
Output Short Circuit Current
Ios
Tj=25
o
C
--
750
--
mA
Peak Output Current
Io peak
Tj=25
o
C
--
2.2
--
A
Temperature Coefficient of
Output Voltage
ΔVout/ ΔTj
Iout=10mA, 0
o
CTj125
o
C
--
-0.6
--
mV/
o
C
TS7806 Electrical Characteristics
(Vin=11V, Iout=500mA, 0
o
CTj125
o
C, Cin=0.33uF, Cout=0.1uF; unless otherwise specified.)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Tj=25
o
C
5.75
6
6.25
Output Voltage
Vout
8.5VVin21V,
10mAIout1A, PD15W
5.7
6
6.3
V
8.5VVin25V
--
5
120
Line Regulation
REGline
Tj=25
o
C
9VVin13V
--
1.5
60
10mAIout1A
--
14
120
Load Regulation
REGload
Tj=25
o
C
250mAIout750mA
--
4
60
mV
Quiescent Current
Iq
Iout=0, Tj=25
o
C
--
4.3
8
8.5VVin25V
--
--
1.3
Quiescent Current Change
ΔIq
10mAIout1A
--
--
0.5
mA
Output Noise Voltage
Vn
10Hzf100KHz, Tj=25
o
C
--
45
--
uV
Ripple Rejection Ratio
RR
f=120Hz, 9VVin19V
59
75
--
dB
Voltage Drop
Vdrop
Iout=1.0A, Tj=25
o
C
--
2
--
V
Output Resistance
Rout
f=1KHz
--
19
--
mΩ
Output Short Circuit Current
Ios
Tj=25
o
C
--
550
--
mA
Peak Output Current
Io peak
Tj=25
o
C
--
2.2
--
A
Temperature Coefficient of
Output Voltage
ΔVout/ ΔTj
Iout=10mA, 0
o
CTj125
o
C
--
-0.7
--
mV/
o
C
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible, and thermal effects must be taken into account separately.
This specification applies only for DC power dissipation permitted by absolute maximum ratings.