User Manual

6-Dec.-2008 Ver.0.5
TAIYO YUDEN Confidential
& Tentative
29/39
TAIYO YUDEN
EY
T
MECS
Control No.
HD-AE-D080137 (7/11)
Control name
Electrical characteristics
Table 5: Link Keys
Item Capability Status Support
1 Creation of link key - Unit Key C.1 Yes
2 Creation of link key - Combination Key C.1 Yes
3 Initiate change of link key O Yes
4 Accept change of link key M Yes
5 (Intentionally left blank) No
6 (Intentionally left blank) No
7 Accept pairing with Unit Key O Yes
C.1: Mandatory to support at least One - either (LMP:5/1) OR (LMP:5/2).
Table 6: Encryption
Prerequisite: 2/3(Encryption supported)
Item Capability Status Support
1 Initiate encryption C.1 Yes
2 Accept encryption requests M.1 Yes
3 (Intentionally left blank) No
4 (Intentionally left blank) No
5 Key size negotiation M.1 Yes
6 Start encryption, as master M.1 Yes
7 Accept start of encryption M.1 Yes
8 Stop encryption, as master M.1 Yes
9 Accept stop of encryption M.1 Yes
10 Encryption Pause/Resume M.1 Yes
M.1: Mandatory IF (LMP:2/3) - (Encryption) is supported.
C.1: Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Optional.
Table 7: Clock offset information
Item Capability Status Support
1 Request clock offset information O Yes
2 Respond to clock offset requests M Yes
Table 8: Slot offset information
Prerequisite: 2/4 (Slot offset)
Item Capability Status Support
1 Send slot offset information C.1 Yes
C.1: Mandatory IF (LMP:13/1) - (Master/Slave switch) supported, ELSE Optional.
Table 9: Timing accuracy information
Prerequisite: 2/5 (Timing accuracy)
Item Capability Status Support
1 Request timing accuracy information O Yes
2 Respond to timing accuracy information requests M.1 Yes
M.1: Mandatory IF (LMP:2/5) - (Timing Accuracy) supported
Table 10: LM version information
Item Capability Status Support
1 Request LM version information O Yes
2 Respond to LM version information requests M Yes