Installation Sheet
29 Page
Installaon
Installaon Manual
Each heater's No.8 DIP switch, located on the center computer board's lower bank of DIP switches,
should be in the OFF position.
The diagram above shows an example of a Multi-Unit controller connected to six water heaters.
The multi-unit controller automatically allocates the unit number (1-10) to each water heater
that is part of the Multi-Unit System. Make sure each 7-Seg LED of all the units’ center computer
boards displays the unit number. The lower LED will illuminate when the heater has linked to the
controller.
In a Multi-Unit System, connect the “[1]” connector and the “[2]” connector with the
communication cable (refer to p. 9) or 18 gauge wire cables. The total cable length can be up to
250 ft (76.2 m) long.
MULTI-UNIT SYSTEM
Multiple 910 models can be combined for a Multi-Unit System, along with the multi-unit controller
100112691(TM-MC02). Each multi-unit controller can control from 2 to 10 units for commercial or
residential applications. For a 10-unit system, the computer can modulate from 15,000 BTU/h to
3.8 million BTU/h.
An individual cut-off switch is recommended for each unit in a Multi-Unit System for the purpose of
maintenance.
Mul-unit
controller
Hot Out
Cold In
Multi-Unit System connection diagram
Multi-unit controller and temperature remote controller wiring:
For detailed instructions on the multi-unit controller, refer to the
instructions that are packaged with the multi-unit controller.
NOTICE
Multi-communication terminals
Each terminal : Max. 4 units
Multi-unit
controller
Communication cable
Water
heater
1
Water
heater
2
Water
heater
3
Water
heater
4
Water
heater
5
Water
heater
6
1
2
123
6
4
5
O
N
123
6
4
5
O
N
1
2
1
2
1
2
1
2
1
2
Temperature
remote
controller
Temperature
remote controller
terminals
DIP switch settings for Multi-Unit System
Lower bank of DIP switches
NO.8: 0FF
(Default)
ON
87654321