Install Instructions

NormalOperation
37Page
DO NOT set to185 °F if you use your water heater in a recirculation system. This
willcausedamagetotheheaterandvoidthewarranty.
(unit:°F)
Thetemperaturehasbeenpresetatthefactoryto120°F(49°C).
Iftemperaturesotherthantheoneslistedaboveare required,theremote controller can providea
couplemoretemperatureoptions.Refertop.7foralistofavailable temperaturesontheremote
controller.
Whentheflow
sensordetectsflowhigherthan0.5GPM,asingleLEDtickmarkontheleftsideofthe
3digit7Seg.LEDwillblinktoindicatethattheunitisworking.
<Howtosetthehotwatertemperatureofthewaterheater>
1. Takeoffthewaterheater’sfrontcover.
2. PresstheeitherIncreasebuttonortheDecreasebuttononthecomputerboardtoincrease
ordecreasethesettemperature.The3digit7Seg.LEDwilldisplaytheavailableset
temperatures.(Figure.1)
3. Scrolltothedesiredsettemperature.



100 105 110 115 120 125 135 140 145 150 155 160 165 170 175 185
Settemperature(Example110
°
F)
Temperaturesavailable
Computerboard
Figure.1
Exam
p
le:tickmarknexttothe110°Fsettem
p
eraturedis
p
la
y
Decreasebutton
3digit7SegLED
Increasebutton