TK-110U Submittal

Page 2 of 4
TBGSS01212
15-150 PSI water pressure. 40 PSI or above recommended for maximum flow.
*Field gas convertible from natural gas to propane. Conversion kit is included with the heater.
**For Propane, minimum inlet gas pressure is 8.0 in W.C. and maximum inlet gas pressure is 14.0 in W.C.
***Current numbers based on factory testing; 0.5 GPM required for activation; 0.4 GPM required for continuous fire after initial ignition.
+Suitable for commercial application.
Indoor models are certified from sea level to 10,100 ft. elevation. Outdoor models are certified from sea level to 6,000 ft. elevation.
MODEL
NUMBER
TYPE*
GAS CONSUMPTION
INPUT
INLET GAS
PRESSURE**
ENERGY
FACTOR
(EF)
MAXIMUM
GPM***
HOT/COLD
CONNECTIONS
GAS
CONNECTION
DIMENSIONS IN INCHES
UNIT
WEIGHT
(LBS)
MINIMUM
BTU/H
MAXIMUM
BTU/H
MINIMUM
IN. W.C.
MAXIMUM
IN. W.C.
HEIGHT WIDTH DEPTH
INDOOR MODELS
TK-110U-I 200
Natural 15,000 140,000 4.0 10.5 0.82 6.6 3/4" NPT 3/4" NPT 20-1/2 13-3/4 10 38
TK-310U-I 200
Natural 15,000 190,000 4.0 10.5 0.82 8 3/4" NPT 3/4" NPT 20-1/2 13-3/4 10 38
TK-510U-I 200+
Natural 15,000 199,000 4.0 10.5 0.82 10 3/4" NPT 3/4" NPT 20-1/2 13-3/4 10 40
OUTDOOR MODELS
TK-110U-E 200
Natural 15,000 140,000 4.0 10.5 0.82 6.6 3/4" NPT 3/4" NPT 20-1/2 13-3/4 9-1/2 38
TK-310U-E 200
Natural 15,000 190,000 4.0 10.5 0.82 8 3/4" NPT 3/4" NPT 20-1/2 13-3/4 9-1/2 38
TK-510U-E 200+
Natural 15,000 199,000 4.0 10.5 0.82 10 3/4" NPT 3/4" NPT 20-1/2 13-3/4 9-1/2 40
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
HOT 4-5/8" (116 mm)
20-1/2" (520 mm)
1" (26 mm)
13-3/4" (350 mm)
10" (254 mm)
1-3/4" (45 mm) 1-3/4" (45 mm)
21-1/2" (545 mm)
1-3/8" (36 mm)
4-3/8" (113mm)
19-3/8" (493 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
HOT 6" (153 mm)
COLD 6" (153 mm)
2-1/4" (58 mm)
3-5/8"(93 mm)
10" (256 mm)
1-7/8" (47 mm)
HOT 5"(127mm)
120VAC 1-7/8" (49 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
5-1/8" (130 mm)
13-1/8" (334 mm)
4-3/8" (113 mm)
AT-KJr3U/K5U/D3U-IN
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
HOT 4-5/8" (116 mm)
20-1/2" (520 mm)
1" (26 mm)
13-3/4" (350 mm)
10" (254 mm)
1-3/4" (45 mm) 1-3/4" (45 mm)
21-1/2" (545 mm)
1-3/8" (36 mm)
4-3/8" (113mm)
19-3/8" (493 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
HOT 6" (153 mm)
COLD 6" (153 mm)
2-1/4" (58 mm)
3-5/8"(93 mm)
10" (256 mm)
1-7/8" (47 mm)
HOT 5"(127mm)
120VAC 1-7/8" (49 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
5-1/8" (130 mm)
13-1/8" (334 mm)
4-3/8" (113 mm)
AT-KJr3U/K5U/D3U-IN
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
HOT 4-5/8" (116 mm)
1" (26 mm)
13-3/4" (350 mm)
10" (254 mm)
1-3/4" (45 mm) 1-3/4" (45 mm)
21-1/2" (545 mm)
19-3/8" (493 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
HOT 6" (153 mm)
COLD 6" (153 mm)
9-1/2" (241 mm)
HOT 5" (127 mm)
120VAC 1-7/8" (49 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
13-1/8" (334 mm)
8" (203 mm)
1-5/8" (43 mm)
AT-KJr3U/K5U/D3U-OS
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
HOT 4-5/8" (116 mm)
1" (26 mm)
13-3/4" (350 mm)
10" (254 mm)
1-3/4" (45 mm) 1-3/4" (45 mm)
21-1/2" (545 mm)
19-3/8" (493 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
HOT 6" (153 mm)
COLD 6" (153 mm)
9-1/2" (241 mm)
HOT 5" (127 mm)
120VAC 1-7/8" (49 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
13-1/8" (334 mm)
8" (203 mm)
1-5/8" (43 mm)
AT-KJr3U/K5U/D3U-OS
INDOOR MODEL DIMENSIONS
CLEARANCES: TOP 12”, BOTTOM 12”, FRONT 4”, BACK 1”, SIDES 3”
OUTDOOR MODEL DIMENSIONS
CLEARANCES: TOP 36”, BOTTOM 12”, FRONT 24”, BACK 1”, SIDES 3”
FRONT VIEW FRONT VIEW
SIDE VIEW SIDE VIEW
BOTTOM VIEW BOTTOM VIEWTOP VIEW TOP VIEW