~ WATER HEATER ~
PROBLEM POSSIBLE SOLUTIONS
Unit does not ignite when water goes
through the unit.
Is the flow rate over 0.5 GPM? (p. 30)
Check for the filter on cold water inlet. (p. 34)
Check for reverse connection and cross connection.
If you use the remote controller, is the power button
turned on? (p. 30)
The fan motor is still spinning after
operation has stopped.
This is normal. After operation has stopped, the fan
motor keeps running for 35 seconds in order to re-
ignite quickly, as well as push all exhaust gas out of
the flue.
Abnormal sounds come from the unit.
Contact the manufacturer at 1-877-737-2840.
~ REMOTE CONTROLLER: 9007606005
(TM-RE30) (OPTIONAL) ~
PROBLEM POSSIBLE SOLUTIONS
Remote controller does not display
anything when the power button is
turned on.
Press the ON/OFF button.
If the lamp lights up
This is normal. When the unit has not operated for
five minutes or more, the display turns off to
converse energy.
If the lamp does not light
Make sure the unit gets power supply.
Make sure the connection to the unit is correct.(p. 21)
An ERROR code is displayed.
Please see the p. 37.
~ EASY-LINK SYSTEM ~
PROBLEM POSSIBLE SOLUTIONS
How are the unit numbers assigned?
For an Easy-Link system, other than the Parent Unit
(which is always labeled #1), all the other units (the
Child units) are numbered randomly.
To check which numbers are assigned to which
units, push the button on the computer board of a
unit as shown below. The unit number will be
displayed on the 7-Seg LED.
Unit# display
button
7-Seg LED