User’s Manual TR3-L4D01-24 Manual No.
Introduction Thank you for purchasing a TR3-L4D01-24 RFID READER/WRITER. Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference. Manual No.
Regulations and Standards FCC This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart B and C of the FCC Rules. FCC ID : MK4TR3-L4D01-24 FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Japan Radio Law Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 RoHS is support Restriction of Hazardous Substances Waste Dispose of the Products as industrial waste. Manual No.
Safety Precautions The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual. Failure to comply with a WARNING may result in serious injury or death. Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved.
Contents 1 Product Overview ...................................................................................................... 1 1.1 2 Names of Parts and Functions ..................................................................................... 2 2.1 2.2 3 Features .............................................................................................................................................. 1 TR3-L4D01-24 .........................................................................
1 Product Overview 1.1 Features 1 Product Overview 1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.
2 Names of Parts and Functions 2.1 TR3-L4D01-24 2 Names of Parts and Functions 2.1 TR3-L4D01-24 ③ ⑨ ① ② ④ ⑤ ⑥ ⑦ ⑨ Manual No.
2 No ① ② ③ Name LED Nameplate RFID sticker ANT1 to ANT24 ④ ⑤ ⑥ ⑦ Power Button DC Jack Connector FCC ID sticker Names of Parts and Functions 2.1 TR3-L4D01-24 Description Displays the status of this product. Production numbers. Specify that the RFID radio waves are radiated. Connect the Antenna cable. Please connect from ANT1. Power ON/OFF. DC +19V input. Connect the RS-232C cable. Production numbers, will be 8-digit serial number.
2 Names of Parts and Functions 2.2 Antenna 2.2 Antenna 2.2.1 TR3-CA033 CA033 is combined by 2 loop sub antennas and a coupler board. ④ Sub Antenna 1 TR3-CA033-1 Sub Antenna 2 TR3-CA033-2 Coupler Board 09019P04 ① ② ⑤ ⑤ ① ① ② ② ⑥ ⑥ ⑥ ③ ⑤ ① No ① ② ③ ④ ⑤ Name Screw holes CN (PH) CN (SMA) ferrite sheet Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Paste on TR3-CA033-1 reverse side. Production numbers, will be 8-digit serial number.
2 Names of Parts and Functions 2.2 Antenna 2.2.2 TR3-CA034 TR3-CA034 is combined by loop antenna and a coupler board. Antenna TR3-CA034 Coupler board 09019P05 ① ② ⑥ ① ⑤ ① ④ ⑥ Antenna TR3-CA034 ③ ⑤ ② ① Reverse side No ① ② ③ ④ ⑤ Name Screw holes CN (PH) CN (SMA) ferrite sheet Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Paste on TR3-CA034 surface side. Production numbers, will be 8-digit serial number.
2 Names of Parts and Functions 2.2 Antenna 2.2.3 TR3-CA044 TR3-CA044 is combined by loop antenna and a coupler board. Antenna TR3-CA044 Coupler board 09019P16 ① ② ① ① ② ⑤ Antenna TR3-CA044 ④ ③ ⑤ ④ ① Reverse side No ① ② ③ ④ Name Screw holes CN (PH) CN (SMA) Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑤ Inspection mark Manual No.
2 Names of Parts and Functions 2.2 Antenna 2.2.4 TR3-CA045 TR3-CA045 is combined by loop antenna and a coupler board. Antenna TR3-CA045 Coupler board 09019P14 ① ② ① ② ① ⑤ ⑤ ④ Antenna TR3-CA045 ③ ④ ① Reverse side No ① ② ③ ④ Name Screw holes CN (PH) CN (SMA) Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑤ Inspection mark Manual No.
3 Setting and connection 3.1 Setting 3 Setting and connection This RFID Reader/Writer product is to be professionally installed by authorized, qualified and service-trained installation personnel only. 3.1 Setting 3.1.1 DeskTop Don’t drop the product. . Injury may result if the product falls or is dropped. 3.1.2 Wall Mounting Must be fastened securely the product with the screws. Don’t install to the high place. Injury may result if the product falls or is dropped. Screw Manual No.
3.2 3 Setting and connection Antenna installation into a host device 3.2 Antenna installation into a host device Incorporate the antenna in enclosure by all means. 3.2.1 Installation example by Screw holes ・TR3-CA033 M3 Screw M3 Screw ・TR3-CA034 Manual No.
3.2 3 Setting and connection Antenna installation into a host device ・TR3-CA044 M3 Screw M3 Screw ・TR3-CA045 Manual No.
3 Setting and connection 3.3 Connection 3.3 Connection This product will connect with the antenna and antenna cables. This product connects with Host Device with the cable. Type of ferrite core and number of turns are specified by compliance for FCC. When providing this product, ferrite cores are already installed in cables. Don’t change the type of ferrite core and number of turns of the cables (Power supply cable, RS-232C cable, Antenna cables).
4 Specifications 4.1 TR3-L4D01-24 4 Specifications 4.1 TR3-L4D01-24 Specifications Item Applicable Japan Radio Law Standards FCC Radio Frequency Parameter ARIB STD-T82 FCC Part 15 Subpart B,C FCC ID : MK4TR3-L4D01-24 RoHS EU RoHS(2002/95/EC) Supports Safety standard EN60950-1(TÜV) Carrier frequency 13.
4 Specifications 4.1 TR3-L4D01-24 Specifications Item Anti-collision Parameter Standards ISO/IEC 15693 ISO/ISC 18000-3 (Mode1) Host Interface RS-232C Item Speed Parameter 9600bps 19200bps 38400bps(※2) 8 None 1 None Data bits Parity Stop bit Flow control Control LED BUZZER Antenna Connector Anti-collision YES 1 LED (green) 1 BUZZER Connector SMB(J)×24 Symbol RF GND Center Contact Shell Connector RS-232C Connector D-SUB 9Pin Pin assignment Pin No.
4 Specifications 4.1 TR3-L4D01-24 Specifications Item Mechanical Dimensions data (W x D x H) Weight Electrical Power data Ambient Conditions Accessories Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range AC Adaptor RS232C Cross-cable Manual No.TDR-MNL-L4D01-24-EN-100 Parameter 260 x 336 x 88.6mm (Protrusions except) approx. 4.5kg Supply Voltage Current consumption Carrier off Consumption 0 to 40 degree :DC+19V±10% :approx. 1.2mA :approx.
4 Specifications 4.1 TR3-L4D01-24 ■ Dimensions Unit:mm Tolerance:±1.0mm ( )is Recommended Dimension Manual No.
4 Specifications 4.2 Antenna 4.2 Antenna 4.2.1 TR3-CA033 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.
4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA033-1 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○TR3-CA033-2 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P04 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.
4 4.2.2 TR3-CA034 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.
4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA034 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P05 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.
4 4.2.3 TR3-CA044 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.
4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA044 433.23 11-Φ3.2 91.11 200 4-R5 5.5 (7.1) Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P16 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.
4 4.2.4 TR3-CA045 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.
4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA045 424 4-R3 84 6.6 (8.2) Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P14 Unit:mm Tolerance:±1mm Substrate thickness : 1.6 mm Manual No.
4 Specifications 4.3 Coupler Cable 4.3 Coupler Cable Coupler Cable (between Antenna to coupler board) TR3-AC-1A-*** Enter the cable length 90mm : 090 120mm : 120 ■ Specifications item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support AWG26 PH-PH 90mm : approx. 0.061dB 120mm : approx. 0.081dB ■ Dimensions (Cable Length) ( )is Recommended Dimension Manual No.
4 Specifications 4.4 Antenna Cable 4.4 Antenna Cable 4.4.1 WIR42696 ■ Specifications item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMA(P)-SMB(J) approx. 0.043dB ■ Dimensions 500 Unit:mm 4.4.2 WIR42763 ■ Specifications Item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMA(P)-SMB(J) approx. 0.051dB ■ Dimensions 600 Unit:mm Manual No.
4 Specifications 4.4 Antenna Cable 4.4.3 09019M16 ■ Specifications Item RoHS Linetype Connector Cable loss Ferrite core Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMB(P)-SMB(P) approx. 0.16dB E04SR0200935A(3 turn) ■ Dimensions WIR42696 or WIR42763 Side TR3-L4D01-24 Side (1730) Unit:mm ( )is Recommended Dimension Manual No.
5.1 5 Accessories AC Adapter(TR3-PWR-19V-2) 5 Accessories 5.
5.2 5 Accessories RS232C Cross-cable(CB-232C-3) 5.2 RS232C Cross-cable(CB-232C-3) Type of ferrite core and number of turns are specified by compliance for FCC. Don’t change and remove the ferrite core. Don’t uses except the bundled RS232C Cross-cable. ■ Specifications Specifications RoHS Connector screw Cable length Ferrite core Connection Parameter EU RoHS(2002/95/EC) Support D-sub 9Pin Inch screw approx. 4.5m ZCAT17300730A(1 turn) Cross-cable ■ Dimension (4500) Host Device ( ex.
6 Maintenance This product is mainly used in electronic components and semiconductors. Therefore, the long-term stable operation, the environment and conditions are expected to defect, as shown below. • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases.
Revision History Revision code 1.00 Date 2015/05/08 Revised contents Original production Manual No.
[URL] [Mail] http://www.takaya.co.jp/ rfid@takaya.co.