Product Brochure
13
Capacity: 100 and 150 amps continuous.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures are available in 16 gauge painted steel finish.
(For aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Terminals are lay-in style, tin-plated, extruded aluminum 6061-T6.
UL: All sockets are UL listed.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
1) Select cover style, enclosure material
UA _ _ _ _ - _ _ _
and number of positions.
2) Select hub style
3) Select options
Consult the factory for other available options such as, but not limited to insulated
5th terminals, alternate jaw guide configuration, alternate hasp material and special labeling.
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
Y = Large Opening
CUSTOMIZED CATALOG NUMBER:
3 = Center Feed
4 = End Feed
5 = Center feed,
LG Hub Open
1 = Ringless, Steel
2 = Ring Style, Steel
3 = Ringless, Al
1 = 100 Amp/position
3 = 160 Amp/position
2 = 2 Gang
3 = 3 Gang
4 = 4 Gang
5 = 5 Gang
6 = 6 Gang
KNOCKOUT DIAGRAMS
KNOCKOUTS (inches):
L: 1/2, 3/4, 1, 1-1/4, 1-1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
RX: x2.750 HUB 0P
Product Schedule 414
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover