Product Brochure
4
Temporary Power Outlet Panels
Build Your Own Catalog Numbering System
a
Required fields.
b
A minimum of 1 receptacle
must be selected. A maxi
-
mum of 3 receptacles, with
up to 125amps total, may be
selected. UL does not allow
field installation of recep
-
tacle kits
.
c
Two receptacle devices ship
in a 7" wide enclosure and are
wired with a 3 circuit interior.
Depending on the receptacle
configuration selected an
additional circuit may or may
not be available
d
Enclosure includes same loop
feed lugs as the pedestal
devices. Enclosure is larger.
Please see knockout dia-
grams for details.
e
Dash is only present if one of
the options listed after the
dash is needed.
f
Light kits are installed by
the factory and require
either a 120V GFCI breaker
or 5-20RGFI receptacle to
power the light fixture.
Cable TV, phone, & water
accessories are purchased
separately and are not config
-
ured as part of the device.
Photocell is factory wired and
is mounted internally. 120V
AC photocell only.
"X" designates alternate
receptacle configuration on
each side. Contact sales office
for pricing.
Custom Options
L
f
Light kit factory
installed
LP
Light kit with
photocell
factory installed
X
Alternate
receptacle
configuration
on double-sided
pedestal
Cx
Custom color
configuration
Enclosure Type
S
Surface mount,
un-metered
S2
d
Surface mount,
un-metered,
loop feed lugs
T
surface mount,
top feed-
metered
B
surface mount,
bottom feed-
metered
P
Direct burial
pedestal
M
Pad mount
pedestal
2P
Direct burial
pedestal, dou-
ble-sided
2M
Pad mount ped-
estal, double
sided
Meter/Bypass
U
Unmetered
R
Ringless,
No Bypass
N
Ring, No Bypass
L*
Ringless,
Lever Bypass
H
Ringless,
Horn Bypass
Main Type
L
Main Lugs, 125A
B
Main Breaker,
125A
D
Main Breaker,
100A
Talon
Temporary
Power
Receptacles (3 max)
1
14-50R 125/250V 50A
1F
Designates GFCI Circuit Breaker
Protection
2
14-30R 125/250V 30A
2F
Designates GFCI Circuit Breaker
Protection
3
TT30R 125V 30A
3F
Designates GFCI Circuit Breaker
Protection
4
L6-30R 250V 30A
4F
Designates GFCI Circuit Breaker
Protection
5
6-20R 250V 20A
5F
Designates GFCI Circuit Breaker
Protection
6
L5-20R 125V 20A
6F
Designates GFCI Circuit Breaker
Protection
7
5-20R2GFI 125V 20A
7X
Designates non-weather-
resistant GFCI receptacle
8
5-20R2 125V 20A
8F
Designates GFCI Circuit Breaker
Protection
8G
Designates weather resistant
receptacle with GFCI Circuit
Breaker Protection
9
L-530R 125V 30A
9F
Designates GFCI Circuit Breaker
Protection
T
–
a eacabaa
Custom Color
Guidelines:
•”Cx" designates
custom color.
Contact sales office
for color code to
insert into part num-
ber to replace the "x"
in this designation.
• Additional charges
apply and depend on
the color needed.
• Custom color
matching available:
Customer must
signoff on painted
sample prior to pro-
duction of order.
• Order cancellations
will involve a fee
after custom paint is
ordered.
Step 1
Start with the power receptacle product line prefix identifier and choose the
main type: (TL)
Step 2
Choose the first receptacle and its circuit breaker type: (1F)
Step 3
Choose the second receptacle and its circuit breaker type: (3)
Step 4
Choose the third receptacle and its circuit breaker type: (7)
Step 5
Choose utility meter & bypass type required: (N)
Step 6
Choose enclosure type: (T)
Step 7
Add dash and select light option with photocell: (-LP)
Given specifications:
n 125A Main Lugs
n 50A, 125/250V receptacle with GFCI
circuit breaker
n 30A, 125V receptacle with a
standard circuit breaker
n 20A, 125V GFCI weather
resistant receptacle
n Ring type meter at the top
n Pedestal mount device
n Light option with photocell
Example: Catalog Number: TL1F37NT-LP
INSTALLER RESPONSIBLE FOR ENSURING UTILITY AND LOCAL CODE ACCEPTANCE
Follow the table below to configure a custom catalog number. Contact your local Talon agent or Siemens sales office for
price and lead time. User assumes all responsibility for selecting proper configuration.
*Lever bypass available
only in surface mount,
topfeed configurations